Foundation Calculators
Design square pad footings or pod-and-rib slab foundations for one- and two-storey houses. Choose from TC1, TC2 and reduced-bearing slab options to suit your geotechnical report, with foundation sizes, calculations and drawings.

Before you start
Have your geotechnical report and structural loading information ready:
- Confirmed foundation suitability and ultimate bearing capacity (150–300 kPa)
- Roof, wall and floor dimensions and loads
- Post or beam reactions for pad design
The calculators
Square Pad Foundation
Design up to five square concrete pad footings using the support reactions from the structure above.
Use it when
- You need separate pads beneath posts or beam supports.
- You have the gravity and wind-uplift reactions for each support.
What it gives you
- Pad width and thickness.
- Reinforcement size and spacing.
- Bearing, uplift and structural checks.
Limits
- Square pads up to 3.0 m wide and 500 mm thick.
- No column base moments or earthquake reactions.
- Punching shear assumes a 90 × 90 mm post.
TC1 Single Storey Foundation
Size foundation ribs for a single-storey house, with pads for up to five point loads.
Use it when
- A single-storey house on a pod-and-rib slab.
- TC1 sites, or good ground confirmed by your geotechnical assessment.
What it gives you
- External and internal foundation rib widths.
- Pad sizes and reinforcement for entered point loads.
- Foundation and pad drawing schedules.
Limits
- Single storey only.
- General rib reinforcement is not designed.
- No TC3, pile foundations or earthquake reactions at pads.
TC2 Single Storey Foundation
Size foundation ribs and reinforcement for a single-storey TC2 slab, including loss-of-support checks.
Use it when
- A single-storey house requiring a TC2 slab design.
- Your geotechnical assessment confirms this foundation type suits the site.
What it gives you
- External and internal rib widths.
- Top and bottom rib reinforcement.
- Ground-bearing and loss-of-support checks.
Limits
- Single storey only.
- No separate point-load or pad design.
- Steel-fibre slab details are not suitable for polished or exposed concrete floors.
Raft Slab Reduced Bearing Single Storey
Size pod-and-rib slab foundations for reduced ground bearing, with one common load-bearing rib width and pads for up to five point loads.
Use it when
- A single-storey house on ground with ultimate bearing capacity from 150 kPa to below 300 kPa.
- Your geotechnical assessment confirms this foundation type suits the site.
What it gives you
- A common width for load-bearing ribs.
- Non-load-bearing rib widths.
- Pad sizes and reinforcement for entered point loads.
Limits
- Single storey only.
- ArchiSuite slab details only; not a proprietary raft-system design.
- General rib reinforcement, settlement and liquefaction are not assessed.
- No earthquake reactions at pads.
What you download
- Structural calculations
- Project summary
- Structural drawings
Not sure whether this calculator suits your site? Contact ArchiSuite.
Try it on your project
Set up your project, enter your inputs and check the results before you pay. Prefer a walkthrough first? Book a short call with the team.