Troubleshooting

Project Settings Missing or Out of Range

Fix messages such as "Roof Pitch is missing or out of range…" or "Project Settings … is required before running this calculation" by completing Project Settings.

On this page

Every calculator reads some of its values from the active project's Project Settings: the site's wind, snow and earthquake zones, elevation, roof pitch, soil class and ground bearing capacity. If a value it needs is blank or outside the accepted range, the calculation is refused before anything is saved.

The messages#

On the lintel forms (before anything is sent)#

Lintel Supporting Roof and Lintel Supporting Roof, Wall and Floor Joists check two settings as soon as you press the analyse button:

  • "Roof Pitch is missing or out of range (0 - 90°) in Project Settings. Please update Project Settings to proceed." Project Settings accepts a roof pitch from 0 to 45 degrees.

  • "Bearing Capacity is missing or out of range (150 - 300 kPa) in Project Settings. Please update Project Settings to proceed."

From the server (all calculators)#

These appear as a toast after you press the analyse or update button:

  • "Project Settings wind zone is required before running this calculation." The same wording is used for the snow zone, elevation, roof pitch, geotechnical ultimate bearing capacity, earthquake zone and soil class.

  • "Project Settings roof pitch must be between 0 and 45 degrees."

  • "Project Settings elevation must be between 0 and 800 m."

  • "Project Settings geotechnical ultimate bearing capacity must be between 150 and 300 kPa."

  • "Project Settings wind zone must be Low, Medium, High, Very high or Extra high."

  • "Project Settings snow zone must be N0, N1, N2, N3, N4 or N5."

  • "Project Settings earthquake zone must be zone 1, 2, 3 or 4." On the bracing portals, the wording ends "…or a supported location name."

  • "Project Settings soil class must be A, B, C, D or E."

Retaining walls#

Retaining walls also need the project's geotechnical information. If it is incomplete, the Geotechnical information required dialog says "Complete the geotechnical report details and soil properties in Project Settings before analysing this retaining wall."

Which settings each calculator needs#

CalculatorsProject Settings read
Lintel Supporting Roof; Lintel Supporting Roof, Wall and Floor Joists; Roof Beam Supporting Roof Framing/TrussesWind Zone, Snow Zone, Elevation, Roof Pitch, Geotechnical Ultimate Bearing Capacity
Floor Beam Supporting FloorGeotechnical Ultimate Bearing Capacity
TC1, TC2, raft slab and square pad foundationsGeotechnical Ultimate Bearing Capacity
Timber pole, cantilever masonry and propped masonry retaining wallsEarthquake Zone, Soil Class, plus the geotechnical report details and soil properties
Bracing portalsEarthquake Zone, Soil Class, Wind Zone, Snow Zone, Elevation, Roof Pitch, Geotechnical Ultimate Bearing Capacity

With Snow Zone set to N0, Elevation can be left blank.

How to fix it#

  1. Click Project Settings in the sidebar.

  2. Under What are you designing?, tick what the project includes: Retaining walls, Beams & lintels, Portal frames or Foundations. The form shows and requires the site fields those calculators read. With nothing ticked, every field is shown and required.

  3. Fill in the missing value. Roof Pitch is 0–45 deg; if the roof has several pitches, use the lowest. Elevation is 0–800 m. Geotechnical Ultimate Bearing Capacity is 150–300 kPa.

  4. For retaining walls, open Geotechnical Properties (Must be completed for retaining wall designs). Fill in:

    • Geotechnical Engineering Company Name, Report Reference / Revision, Report Title and Report Date;

    • the four soil properties: Backfill soil friction angle, φb, Backfill soil unit weight, γb, Founding soil friction angle, φf and Founding soil unit weight, γf.

    Placeholder text such as "TBC" or "N/A" does not count.

  5. Press Update Project.

  6. Go back to the calculator and press the analyse or update button again.

After you change a setting#

On the two lintels, the floor beam and the roof beam, a calculation assessed with the old settings is marked out of date. It shows "Project Settings changed - press Update Assessment." followed by the settings that changed. Until you reassess it, you cannot select a member, accept, pay or download. Press the form's update button, select the member again and press Accept.

If you cannot change Project Settings#

  • "Project Settings are locked: this project has been paid for. The project details and the site information already recorded stay locked, including for calculations added or revised later. You can still choose what you are designing and complete the settings it needs that were left blank. Contact ArchiSuite to request a correction." Only the blank settings your What are you designing? categories need can still be filled in. See Project Settings.

  • "A paid calculation on this project relies on this setting, so it cannot be changed here. Contact ArchiSuite to request a reviewed correction." under a field: a paid calculation relies on it.

  • "Project Settings cannot be changed while a payment for this project is in progress." Complete the open payment, or wait until that checkout expires.

If no project is active, the calculator shows Create a project first or Choose a project. See Create a project.