How-to

Project Settings

Every field on the Project Settings page - what it means, the accepted options and limits, which calculators use it, and what happens to existing calculations when you change it.

On this page

Project Settings hold the job details and the site information your calculators read. Get them right before you analyse anything: every calculation in the project uses them, and after the first payment the values already recorded lock for the whole project.

Open Project Settings#

Click Project Settings in the sidebar. It always shows your active project. You can also click Project Settings under Primary Project: on Team Projects, or open any project from the list to see the same form as Edit Project.

Admins and Editors can change Project Settings. Viewers can look but not save.

If no project is active, you see Create a project first or Choose a project instead. See Create a project.

Project Settings

Basic Information#

These identify the job. They are printed on the project's documents.

  • Project Name, Job Number, Client Name — all required. Job Number is your own job number.

  • Description — optional notes about the project.

  • Project Address — type the street address and pick it from the list. Choosing an address looks up the parcel to fill Lot/DP, suggests the Territorial Authority, and looks up the ground height for Elevation.

  • Lot/DP — required. ArchiSuite never overwrites a Lot/DP you typed. If the parcel record differs, you can click Use the parcel record.

  • Territorial Authority — required. If it doesn't match the address, a warning ending "Check the Territorial Authority." appears, with a button to use the suggested council.

What are you designing?#

Tick what the project includes ("Select all that apply"). The form then shows only the site settings those calculators read. Fields you hide keep their saved values.

You tickSite Parameters shown
Retaining wallsEarthquake Zone, Soil Class. Also opens Geotechnical Properties and marks it required
Beams & lintelsWind Zone, Snow Zone, Elevation, Roof Pitch, Geotechnical Ultimate Bearing Capacity
Portal framesAll seven site parameters
FoundationsGeotechnical Ultimate Bearing Capacity
NothingAll seven site parameters, all required

This is a setup aid only. If you later run a calculator that needs a setting you hid and left blank, it asks you to complete it.

Site Parameters#

SettingOptions or limitsUsed by
Earthquake Zone1, 2, 3 or 4Retaining walls and bracing portals
Soil ClassA, B, C, D or ERetaining walls and bracing portals
Wind ZoneLow, Medium, High, Very high, Extra highBoth lintels, the roof beam, bracing portals
Snow ZoneN0, N1, N2, N3, N4, N5Both lintels, the roof beam, bracing portals
Elevation0 - 800 m (not used in N0)Both lintels, the roof beam, bracing portals
Roof Pitch0 - 45 deg (not used in N0)Both lintels, the roof beam, bracing portals
Geotechnical Ultimate Bearing Capacity150 - 300 kPaLintels, beams, foundations and bracing portals

In detail:

If a calculator needs a setting that is blank or out of range, Analyse is refused with a message such as Project Settings wind zone is required before running this calculation. or Project Settings roof pitch must be between 0 and 45 degrees. See Project Settings missing.

Geotechnical Properties#

This card is collapsed and marked Geotechnical Properties (optional) unless you tick Retaining walls. Then it stays open as Geotechnical Properties (Must be completed for retaining wall designs). As the card says, this information is transferred onto the drawings.

  • Geotechnical Engineering Company Name

  • Report Reference / Revision

  • Report Title

  • Report Date

  • Backfill soil friction angle, φb — 20 - 36° (definition)

  • Backfill soil unit weight, γb — 14 - 20 kN/m³ (definition)

  • Founding soil friction angle, φf — 20 - 36° (definition)

  • Founding soil unit weight, γf — 14 - 20 kN/m³

The three retaining wall calculators need all eight fields filled in before they analyse. Otherwise you see Geotechnical information required: "Complete the geotechnical report details and soil properties in Project Settings before analysing this retaining wall."

Each wall calculator can accept a narrower range for its own soil inputs. If the soil values you enter in a wall calculator differ from these, you see Check geotechnical values: "These inputs differ from the project geotechnical properties. Check they are suitable before continuing." Click Review inputs to go back, or Continue to analyse with the calculator's values. Project Settings are not changed.

Change a setting#

  1. Make sure the project you want is the active project.

  2. Click Project Settings in the sidebar.

  3. Change the fields.

  4. Click Update Project. You see Project updated successfully.

If anything is missing or out of range, nothing is saved. You see Not saved: (or Not saved - 2 fields need attention:) with the reasons, and the first problem field is highlighted.

What happens to existing calculations#

Lintels, the floor beam and the roof beam. For Lintel Supporting Roof, Lintel Supporting Roof, Wall & Floor Joists, Floor Beam Supporting Floor and Roof Beam Supporting Roof Framing/Trusses, ArchiSuite records the settings each assessment used. These are the wind zone, snow zone, elevation, roof pitch and bearing capacity (the floor beam uses the bearing capacity only).

If you change one of them afterwards, the calculation shows:

Until you open the calculation and press its update button, you can't select a member, accept it or pay for it. Accepted calculations that are out of date are flagged in Project Outputs. Calculations that don't use the changed setting are not affected.

Other calculators (retaining walls, foundations and bracing portals) read Project Settings each time you analyse. To use new values, open each calculation and run it again with its update button.

Clearing a setting that a calculation needs doesn't mark it as changed. The calculator asks you to complete the setting instead.

Locked after payment#

Project Settings lock after the project's first successful payment, for the whole project. This includes calculations you add or revise later. Before you pay, ArchiSuite warns you: Project settings will lock after payment.

Once locked, the page shows "Project Settings are locked: this project has been paid for. The project details and the site information already recorded stay locked, including for calculations added or revised later. You can still choose what you are designing and complete the settings it needs that were left blank. Contact ArchiSuite to request a correction."

What stays locked:

  • The project details in Basic Information. They show a lock icon.

  • Every site and geotechnical setting that had a value when you paid.

  • A blank setting that a paid calculation on the project relies on. Under it you see "A paid calculation on this project relies on this setting, so it cannot be changed here. Contact ArchiSuite to request a reviewed correction."

What you can still change:

  • What are you designing? Tick or untick categories at any time. Unticking one only changes which fields the form shows and requires. It deletes no calculation, value or document.

  • A site or geotechnical setting that was blank when you paid and that a category you have ticked needs. You can fill it in, and correct it, until a calculation that reads it is paid for.

Locked fields are greyed out. Click Update Project to save what you added.

While a payment is in progress, you see "Project Settings cannot be changed while a payment for this project is in progress."

Delete the project#

Admins can click Delete Project at the bottom of the page. See Create a project for what happens.

Common problems#

  • Earthquake zone is required, Soil class is required, Wind zone is required, Snow zone is required, Elevation is required, Roof pitch is required, Geotechnical Ultimate Bearing Capacity is required — fill in the field. Tick fewer What are you designing? categories if the project doesn't need it.

  • Elevation must be between 0 and 800 m — sites above 800 m are outside the calculators' scope. See When no calculator fits.

  • Roof pitch must be between 0 and 45 degrees — for several pitches, use the lowest.

  • Bearing capacity must be between 150 and 300 kPa — check the ultimate value in your geotechnical report.

  • Must be between 20 - 36° or Must be between 14 - 20 kN/m³ — a soil property is out of range.

  • Project settings are locked after payment and cannot be edited. Contact ArchiSuite to request a correction. — the project has been paid for and you tried to change a locked setting. See Locked after payment above.

  • A paid calculation on this project relies on this setting, so it cannot be changed here. Contact ArchiSuite to request a reviewed correction. — a calculation that has been paid for reads this setting, so changing it could change what was paid for. ArchiSuite can make a reviewed correction.

  • Permission denied — Viewers can't change Project Settings.

Was this helpful?