A structural calculation, a producer statement (PS1) and a certificate of design work (Form 2A) do different jobs, and one doesn't replace another. When building work needs consent and includes restricted building work, such as the design of a house's foundations, beams, lintels, bracing or roof structure, the law requires a Form 2A from the licensed person who carried out or supervised that design work. Using a manufacturer's calculator or an online design tool doesn't change that, and it doesn't hand the certificate to the software provider. Who signs depends on who actually carried out or supervised each part of the design.

What does the Building Act require?#

Under section 45(2) of the Building Act 2004, design work that is restricted building work must be carried out or supervised by appropriately licensed building practitioners. Under section 45(3), the plans and specifications must come with a certificate of work that:

  • is provided by the licensed practitioner who carried out or supervised the design work

  • identifies the design work it covers

  • states that the design complies with the Building Code, or identifies any waivers or modifications needed.

The Building (Definition of Restricted Building Work) Order 2011 makes design of the primary structure of a house or small-to-medium apartment building restricted work. That covers foundations, beams, columns, lintels, bracing, walls and the roof structure.

The law doesn't require the overall building designer to calculate every element personally. Design work can be carried out or supervised by different licensed people, provided the certificates record who is responsible for what.

What did Determination 2023/008 decide about software-designed trusses?#

MBIE Determination 2023/008 concerned a single-storey house with proprietary prefabricated roof trusses. The council refused to grant consent without a certificate of work covering the truss design, and the applicant argued the trusses were designed with proprietary software that a typical designer couldn't operate. MBIE found:

  • Roof trusses carry loads to the supporting structure, so they're part of the primary structure (paragraph 5.12).

  • Truss design is therefore restricted building work, and a certificate of work is required. Using proprietary software doesn't remove it from that requirement (paragraph 5.13).

  • Off-site manufacture is different from design. Manufacture may fall outside the restricted building work rules, but that doesn't extend to the design (paragraph 5.14).

  • The council wasn't insisting that the lead designer provide the truss certificate. An appropriately licensed designer, potentially the truss designer, could (paragraph 5.15).

  • The certificate had to cover the roof structure including the trusses, from a practitioner licensed to carry out or supervise that design (paragraph 6.1).

The determination didn't decide that every software provider must issue a Form 2A for every calculation, and it didn't settle the supervision arrangements between the designers. The rule it applies is that restricted design work must be covered by a certificate from a licensed person who carried out or supervised it.

Can a designer use calculations prepared by someone else?#

Yes. It's normal for designers to use specialist calculations, such as truss designs from fabricators, manufacturers' beam designs or an engineer's specific design. LBP guidance says that when a designer incorporates trusses into the building design, their certificate should clearly show how. A designer who takes responsibility for someone else's calculation needs a genuine basis for doing so. Typically they check:

  • the design loads suit the building

  • the supporting structure can carry the loads the element imposes

  • the design assumptions match the project

  • the connections and load paths are dealt with

  • the element is appropriate for its intended use

  • the documents state the standards, assumptions and limits used.

Attaching a calculation or a manufacturer's document isn't, on its own, evidence of adequate supervision. LBP guidance also says that where separate licensed specialists carry out distinct parts of the restricted design work, each signs their own certificate for their part. So separate certificates may be needed.

How do manufacturers' calculations and producer statements fit with Form 2A?#

Manufacturers often supply calculations, fixing details and a producer statement for their structural product. For example, Prolam's Specifier generates consent documents, including PS1 statements, for its glulam products. A supplier or its engineer can certify a particular element without being responsible for the whole building design.

Where your designer incorporates that element:

  • they can reference the supporting documents, including the PS1, in their certificate of design work. MBIE recommends attaching producer statements to the certificate and listing them, and LBP guidance says a design LBP may reference an engineer's or manufacturer's producer statement when an engineered element is used in their design

  • whoever signs the certificate takes responsibility for what it covers

  • a manufacturer's PS1 doesn't replace the certificate of design work. The restricted design work still has to be covered by a Form 2A.

What's the difference between a calculation, a PS1 and Form 2A?#

DocumentPurposeWho provides it
Structural calculation reportShows the analysis, member sizing, assumptions, capacities and checksThe designer, engineer or the person using a calculation tool
PS1 (producer statement – design)A professional opinion, on stated grounds, that specified parts of a design will meet the Building CodeA suitably qualified design professional, usually an engineer
Form 2A (certificate of design work)The prescribed statutory certificate identifying the restricted design work carried out or supervised, with the compliance statementA licensed design LBP, registered architect or Chartered Professional Engineer

A PS1 isn't required for every consent. Producer statements have no prescribed status under the Building Act, but councils commonly accept them as evidence. A Form 2A is a prescribed form, required whenever restricted design work is involved. Providing a PS1 doesn't remove the need for a Form 2A, and a Form 2A on its own doesn't prove the design complies. The council still decides whether it has reasonable grounds.

An ArchiSuite package contains calculations, drawings and a Project Summary. For the design calculators, the Project Summary includes a PS1 signed by a Chartered Professional Engineer for Structural Engineering Solutions Limited (SES), under a separate engagement between you and SES. The PS1 covers the elements in your accepted calculations, within the scope, assumptions and limits stated in it and its Schedule.

ArchiSuite doesn't issue a certificate of design work.

  • The calculation report isn't a Form 2A, and using a calculation tool doesn't transfer the designer's certification obligations to the software provider.

  • If your project is restricted building work, it must be carried out or supervised by an appropriately licensed person and covered by a certificate of design work. ArchiSuite's documents and the SES PS1 can be referenced in that certificate as supporting evidence.

  • The person who certifies must check that the calculated solution suits the project: the loading, span, bearing, supports, connections and other design assumptions.

  • If your council asks for a separate certificate from the engineer who signed the PS1, contact ArchiSuite.

  • If you're not a licensed designer and the work is restricted building work, you'll need a licensed designer to provide the certificate. ArchiSuite's documents don't replace it.

Common questions#

Do I need a PS1 for every beam or lintel? No. The consent application needs enough evidence to show the Building Code will be met. Depending on the design method, that may be an Acceptable Solution such as NZS 3604, calculations, or specialist engineering documents. The council can ask for more.

Can a designer use software calculations? Yes, if the outputs suit the intended use. The designer must understand and check the assumptions, limits and how the result is applied.

Does a manufacturer's PS1 replace Form 2A? No. It can support the documents referenced on the Form 2A, but it doesn't replace the certificate.

Does the structural engineer always need to provide a separate Form 2A? Not necessarily. It depends on who carried out or supervised the restricted design work and how responsibility is documented. Separate certificates may be needed where different practitioners carry out distinct parts.

Who signs Form 2A when a proprietary beam calculator is used? The licensed person who carried out or supervised that restricted design work. It depends on the actual design arrangements, not on which company supplied the software.

Key points#

  • A calculation, a PS1 and a Form 2A serve different purposes and aren't interchangeable.

  • Restricted design work must be covered by a Form 2A from the licensed person who carried out or supervised it.

  • Determination 2023/008 confirms that software-designed roof trusses are restricted design work needing a certificate.

  • Designers may reference others' calculations and producer statements in their certificate, but they take responsibility for what they certify.

  • ArchiSuite doesn't issue Form 2A. Its documents, including the SES PS1, support the certificate your designer provides.

This article gives general guidance about New Zealand building consent documents. The right certification depends on the building, the scope of work and the design arrangements.

Sources

  1. Building Act 2004 (version as at 8 October 2026), ss 7 'supervise', 45(2)-(3A), 49, 84 (opens in a new tab) - New Zealand Legislation (accessed 21 November 2026)
  2. Building (Definition of Restricted Building Work) Order 2011 (as at 15 January 2026), cl 3 'primary structure', cl 6 (opens in a new tab) - New Zealand Legislation (accessed 21 November 2026)
  3. Building (Forms) Regulations 2004, Form 2A Certificate of design work (opens in a new tab) - New Zealand Legislation (accessed 21 November 2026)
  4. Determination 2023/008: refusal of a building consent because a certificate of work for roof truss design was not provided (1 May 2023), paras 5.12-5.15, 6.1 (opens in a new tab) - MBIE (accessed 21 November 2026)
  5. Design process: who must provide a certificate of work; supervision of design RBW; design of trusses (opens in a new tab) - MBIE (lbp.govt.nz) (accessed 21 November 2026)
  6. Codewords 99: Certificates of work and documenting collaborative design (Feb 2021) (opens in a new tab) - MBIE (lbp.govt.nz) (accessed 21 November 2026)
  7. Producer statements: how certificates of work and producer statements work together (last updated 6 Dec 2022) (opens in a new tab) - MBIE (building.govt.nz) (accessed 21 November 2026)
  8. Practice Note 1: Guidelines on Producer Statements (2014) (opens in a new tab) - ACE New Zealand and Engineering New Zealand (accessed 21 November 2026)
  9. Prolam Specifier (generates consent documents 'including PS1 statements') (opens in a new tab) - Prolam (accessed 21 November 2026)

General information about New Zealand rules, not advice for a particular project. Your council confirms whether your project needs building consent, and a suitably qualified professional should check any design.

Was this helpful?