Building & Engineering
Do you need building consent for a retaining wall?
Not if it retains 1.5 m or less of ground and carries no surcharge such as a driveway, building or slope above. It must still meet the Building Code.
- Author
- ArchiSuite
- Checked against sources:
- Published:
On this page
Usually not, if the wall holds back no more than 1.5 metres depth of ground and does not support any surcharge or extra load, such as a driveway, parking, a building, a pool, another wall or ground sloping up behind it. That is exemption 20 in Schedule 1 of the Building Act 2004. In rural zones a wall up to 3 metres can also be exempt, but only if a Chartered Professional Engineer designs or reviews it. An exempt wall must still comply with the Building Code, and district plan rules can still apply.
What does the law actually say?#
Schedule 1, clause 20 of the Building Act 2004 (opens in a new tab) (version as at 8 October 2026) exempts building work on a retaining wall that both:
retains not more than 1.5 metres depth of ground, and
does not support any surcharge or any load additional to the load of that ground. The Act gives "the load of vehicles" as an example.
Both conditions must be met. This exemption has not changed in the recent rounds of Schedule 1 amendments (2020, 2025 and the 2026 granny flat changes).
A second exemption, clause 41, covers retaining walls in a rural zone that retain up to 3 metres of ground and sit at least the wall's own height away from any legal boundary or existing building. It sits in Part 3 of Schedule 1, so it only applies when a Chartered Professional Engineer (CPEng) has designed or reviewed the wall and it is built to that design (section 42A). "Rural zone" excludes rural residential areas.
How do you measure the 1.5 m?#
MBIE's exemptions guidance (opens in a new tab) (sixth edition, January 2026) describes the limit as 1.5 metres measured vertically. In practice, that is the difference in ground level between the low side of the wall and the ground held up behind it. It is not the length of the posts or blocks.
If the height varies along the wall, check the tallest point. MBIE's example is a wall ranging from 900 mm to 1.8 m: the part over 1.5 m needs consent.
What counts as a surcharge?#
MBIE's guidance says the exemption does not apply where the wall is subject to an additional load or surcharge, such as:
vehicle driveways and parking spaces
swimming pools
buildings
other retaining walls
sloping ground above the top of the wall.
The guidance adds that gently sloping ground may not count as surcharge. It suggests getting professional advice, for example from a CPEng, if you are unsure.
MBIE determinations have treated surcharge as load above the level of the top of the wall. That includes permanent loads like buildings and occasional loads like vehicles. In Determination 2021/021 (opens in a new tab), MBIE also decided that the surcharge that counts is the one that exists, or is sure to exist, when the wall is built, not a possible future development next door.
Terraced walls can each be exempt if they are far enough apart that the upper wall doesn't load the lower one. MBIE's example is three 1.2 m crib walls with enough horizontal separation.
What about fences on top and walls on a boundary?#
A fence is a separate exemption (clause 21): up to 2.5 metres high, measured from the supporting ground directly below it, and not a pool fence. Many district plans need resource consent for fences over a certain height, often about 2 metres. Boundary fences also have to meet the Fencing Act 1978.
Neither the Act nor MBIE's guidance specifically says whether a fence fixed to the top of a retaining wall is a surcharge. A fence adds its own weight and wind load to the wall, so the wall has to be built to carry it either way. If you plan anything more than a light fence, ask your council how it treats it before you build.
Clause 20 has no boundary set-back. However, the Building Code (clause B1) aims to protect other property from damage caused by structural failure. A wall near a boundary needs particular care, especially if the neighbour's driveway or house is above it.
Exempt doesn't mean "no rules"#
The Building Code still applies. Section 17 requires all building work to comply with the Building Code, whether or not consent is needed. Section 42A makes compliance a condition of every exemption.
Drainage. MBIE's guidance expects exempt walls to include drainage for ground water.
Safety barriers. Building Code clause F4 requires a barrier where people could fall 1 metre or more, with limited exceptions. MBIE notes this can apply to retaining walls.
District plan rules. Earthworks, height and yard rules can trigger a resource consent. That system is still the Resource Management Act 1991, which is being replaced in stages by the Planning Act 2026. See building consent vs resource consent.
Records. MBIE suggests giving your council drawings and photos of exempt work so the property file is accurate when you sell.
If you're not sure the wall is exempt, you can still apply for building consent.
Worked examples#
| Situation | Consent needed? | Why |
|---|---|---|
| 1.2 m timber wall, level lawn behind | No (exemption 20) | Under 1.5 m, no surcharge |
| 1.2 m wall with a driveway along the top | Yes | Vehicle load is a surcharge (MBIE example) |
| Wall varying from 0.9 m to 1.8 m | Yes, for the part over 1.5 m | Exceeds the height limit (MBIE example) |
| Three 1.2 m terraced walls, well separated | No | No wall loads the one below (MBIE example) |
| Rural 2.5 m wall, 3 m from the house, CPEng-designed | No (exemption 41) | Under 3 m, distance at least its height |
| Rural 3 m wall, 1 m from the house, CPEng-designed | Yes | Closer to the house than its own height (MBIE example) |
What to do next#
Measure the retained height at the tallest point.
List everything within reach of the top of the wall: driveways, parking, buildings, pools, other walls and sloping ground.
If any of these apply, or the height is over 1.5 m, plan for building consent and engineering design. See when a retaining wall needs engineering design.
Check the district plan for earthworks, height and boundary rules.
If you're unsure, ask your council or a CPEng before you start.
Key points#
Exempt: retains 1.5 m or less of ground and carries no surcharge (Schedule 1, clause 20).
Driveways, parking, buildings, pools, other walls and sloping ground above the wall are surcharge examples in MBIE's guidance.
Rural walls up to 3 m can be exempt only with CPEng design or review and enough distance from boundaries and buildings (clause 41).
Exempt walls must still comply with the Building Code, including structure, drainage and fall barriers.
Resource consent rules apply separately.
Sources
- Building Act 2004 (version as at 8 October 2026) - sections 17 and 42A, Schedule 1 clauses 20, 21 and 41 (opens in a new tab) - New Zealand Legislation (accessed 20 November 2026)
- Building work that does not require a building consent - Exemptions guidance for Schedule 1 of the Building Act 2004 (sixth edition, version 2, January 2026), sections 9.1, 13.2 and 13.3 (opens in a new tab) - MBIE (building.govt.nz) (accessed 20 November 2026)
- Determination 2021/021 - withdrawal of a notice to fix for a retaining wall near a boundary, Cromwell (opens in a new tab) - MBIE (building.govt.nz) (accessed 20 November 2026)
- Building Regulations 1992, Schedule 1 (Building Code) clauses B1 and F4 (version as at 15 January 2026) (opens in a new tab) - New Zealand Legislation (accessed 20 November 2026)
- Resource Management Act 1991 (version as at 30 October 2026) - section 9 (opens in a new tab) - New Zealand Legislation (accessed 20 November 2026)
General information about New Zealand rules, not advice for a particular project. Your council confirms whether your project needs building consent, and a suitably qualified professional should check any design.