Calculator guide · CALC-011
Timber Pole Retaining Wall (superseded)
Design a timber pole retaining wall for up to five retained heights. Get pole sizes, hole diameters, embedment depths and timber rail options for each height.
Video: a worked example
On this page
The Timber Pole Retaining Wall calculator designs a timber pole wall with timber rails for up to five retained heights in one calculation. For each height it gives the pole size, the hole diameter and the embedment depth. It also gives a table of timber rail options.
Before you start#
This calculator reads these values from the active project's Project Settings:
Earthquake Zone and Soil Class. These are used for the earthquake load case. If either one is blank or not a supported value, the calculation is refused.
The Geotechnical Properties section. Fill in all four report details (Geotechnical Engineering Company Name, Report Reference / Revision, Report Title, Report Date) and all four soil properties (Backfill soil friction angle, φb, Backfill soil unit weight, γb, Founding soil friction angle, φf, Founding soil unit weight, γf). A retaining wall cannot be analysed until every one of these is filled in. Save with Update Project.
Project Settings accepts soil friction angles from 20° to 36°. This calculator is stricter for the backfill: it needs Backfill soil friction angle, φb between 26° and 36°.
Have these ready from the site and the geotechnical report:
Each retained height you want designed, in mm (up to five).
The slope of the ground behind the wall, and any permanent surcharge on it.
The backfill and founding soil friction angles and unit weights. These are normally the same values you entered in Project Settings.
The pole spacing you want, and the wall case that describes the wall's situation.
Step by step#
In the sidebar, click All Calculators. Choose the Retaining Walls tab, then the Timber Retaining Wall card.
On the Timber Retaining Walls page, click New Timber Wall. If the project has no timber walls yet, click Add Timber Retaining Wall.
In General Info, enter a Calculation Name (for example
TPRW1).In Retained Heights (A), enter Height 1 in mm. Click Add Height to add more, up to five. Use the bin icon to remove a height.
In Geotechnical & Soil Parameters, enter Ground slope, Permanent surcharge, Backfill soil unit weight, γb, Backfill soil friction angle, φb, Founding soil friction angle, φf and Founding soil unit weight, γf.
In Structural & Layout Parameters, enter Pole spacing and choose the Wall case. No case is selected at first: choose the one that describes the wall's situation. Analyse Data is refused until you do.
Click Analyse Data. ArchiSuite first reads the latest saved Project Settings:
If the geotechnical information is incomplete, Geotechnical information required opens and nothing is analysed. Click Close, complete Project Settings, then come back and click Analyse Data again. Your form values are kept.
If your soil inputs differ from the project's soil properties, Check geotechnical values opens. Click Review inputs to go back and change them. Or click Continue to analyse with the values exactly as you entered them.
The Summary table appears below the form, with one row per height. Check that every row shows Pass.
Click Accept. You will see "Calculation accepted successfully!", the button changes to Accepted, and the calculation is added to Project Outputs.
To change a saved calculation, open it from the Timber Retaining Walls list. Edit the inputs and click Update Analysis.
The inputs#
Retained Heights (A). Each height is the retained height of soil the wall holds back, in mm. Each height is designed on its own, with the same soil, surcharge, spacing and wall case. For example, use extra heights along a stepped wall.
Geotechnical & Soil Parameters. Ground slope is the slope of the ground behind the wall, from 0° (level) to 20°. Permanent surcharge is a load that is always on the ground behind the wall, from 0 to 12 kPa. The backfill values describe the soil behind the wall: Backfill friction angle and soil unit weight. The founding values describe the natural ground the poles are embedded in: Founding friction angle and the founding soil unit weight. The backfill values drive the soil pressure on the wall. The founding values drive the ground's resistance around the embedded poles. A calculation saved with a single soil unit weight, before the two were separated, opens with that value in both unit weight fields.
Structural & Layout Parameters. Pole spacing is the centre-to-centre distance between poles, from 1.2 m to 1.5 m. One spacing applies to every height in the calculation. The Wall case offers Cases 3, 4, 5 and 6. Click the (i) beside Wall case to open the ArchiGuide drawer. It shows the six cases of Figure 4.1 from Module 6 (NZGS / MBIE): Case 1, retaining wall integral to building; Case 2, retaining wall supporting building; Case 3, retaining wall supporting foundation; Case 4, retaining wall protecting building up-slope; Case 5, retaining wall facilitating access and services to building; Case 6, other situations where H* > 3 m. The drawer notes that Cases 1 and 2 are outside this calculator's scope. Click a figure to enlarge it.
| Input | Accepted values | Required |
|---|---|---|
| Height 1 | more than 0 and up to 3000 mmIf not: “Must be ≤ 3000 mm” | Yes |
| Height 2 | more than 0 and up to 3000 mmIf not: “Must be ≤ 3000 mm” | No |
| Height 3 | more than 0 and up to 3000 mmIf not: “Must be ≤ 3000 mm” | No |
| Height 4 | more than 0 and up to 3000 mmIf not: “Must be ≤ 3000 mm” | No |
| Height 5 | more than 0 and up to 3000 mmIf not: “Must be ≤ 3000 mm” | No |
| Ground slope above, ω(°) | As shown on the form | Yes |
| Permanent surcharge, qp(kPa) | As shown on the form | Yes |
| Soil unit weight, γ | 14 to 20 kN/m³If not: “Maximum is 20 kN/m³” | Yes |
| Founding soil unit weight, γf | 14 to 20 kN/m³If not: “Maximum is 20 kN/m³” | No |
| Backfill friction, φb(°) | As shown on the form | Yes |
| Founding friction, φf(°) | As shown on the form | Yes |
| Pole spacing, s(m) | As shown on the form | Yes |
| Seismic wall case | As shown on the form | Yes |
- Height 1Required
more than 0 and up to 3000 mm
If not: “Must be ≤ 3000 mm”
- Height 2Optional
more than 0 and up to 3000 mm
If not: “Must be ≤ 3000 mm”
- Height 3Optional
more than 0 and up to 3000 mm
If not: “Must be ≤ 3000 mm”
- Height 4Optional
more than 0 and up to 3000 mm
If not: “Must be ≤ 3000 mm”
- Height 5Optional
more than 0 and up to 3000 mm
If not: “Must be ≤ 3000 mm”
- Ground slope above, ωRequired
°
- Permanent surcharge, qpRequired
kPa
- Soil unit weight, γRequired
14 to 20 kN/m³
If not: “Maximum is 20 kN/m³”
- Founding soil unit weight, γfOptional
14 to 20 kN/m³
If not: “Maximum is 20 kN/m³”
- Backfill friction, φbRequired
°
- Founding friction, φfRequired
°
- Pole spacing, sRequired
m
- Seismic wall caseRequired
As shown on the form
Read from Timber Pole Retaining Wall (CALC-011, version 2.8.0) as it runs today. The form may also show its own limit beside an input.
Worked example#
This is a representative example taken from ArchiSuite's own tests. It is not a design for your site.
Project Settings: Earthquake Zone 2 and Soil Class C. The geotechnical report details are complete, with all four soil properties set to φ 30° and γ 18 kN/m³.
Inputs: Height 1 1000, Height 2 2000, Height 3 3000 mm; Ground slope 0°; Permanent surcharge 5 kPa; backfill and founding unit weights 18 kN/m³; backfill and founding friction angles 30°; Pole spacing 1.2 m; Seismic wall case Case 3.
Because the soil inputs match Project Settings, the analysis runs without a prompt. The Summary shows:
| Case | Hr | SED/Dp | Hole Ds | Embedment L | Status |
|---|---|---|---|---|---|
| H1 | 1,000 mm | 150 mm | 350 mm | 1.6 m | Pass |
| H2 | 2,000 mm | 275 mm | 450 mm | 2.9 m | Pass |
| H3 | 3,000 mm | 325 mm | 500 mm | 4.1 m | Pass |
Each row also shows Spacing S as 1.20 m.
Results#
The Summary table has one row per height:
Case: H1 to H5, in the order you entered the heights.
Hr: the retained height.
SED/Dp: the pole size (small end diameter).
Hole Ds: the hole diameter.
Spacing S: the pole spacing you entered.
Embedment L: the embedment depth of the pole.
Status: Pass or Fail. A height that fails shows "-" instead of sizes.
The calculator picks a pole density for each height. If a normal-density pole would need a small end diameter of 300 mm or more, it is redesigned as a high-density pole. The drawing schedule lists the pole density for each passing height. The timber rail table gives rough sawn and SG8 (wet) rail options, each with its maximum retained height. This table comes from the first height that passes.
After you accept, the calculations, project summary and drawings are prepared from Project Outputs. See Pay for and download your documents.
Limitations#
Up to five retained heights, each more than 0 mm and no more than 3000 mm.
Ground slope from 0° to 20°, and Permanent surcharge from 0 to 12 kPa.
Pole spacing from 1.2 m to 1.5 m. One spacing is used for all heights.
Wall cases 3 to 6 only.
The only load input is a uniform permanent surcharge. There are no inputs for line loads, point loads or groundwater pressure.
Only heights that pass are included in the drawing. The timber rail options come from the first height that passes.
Common errors and how to fix them#
Geotechnical information required: "Complete the geotechnical report details and soil properties in Project Settings before analysing this retaining wall." Fill in every field in the Geotechnical Properties section of Project Settings, save, and analyse again. Example text and fillers such as "TBC" do not count. See Project Settings missing.
Check geotechnical values: "These inputs differ from the project geotechnical properties. Check they are suitable before continuing." Click Review inputs and correct the values. Or, if the different values are intended, click Continue.
"Project Settings could not be loaded, so the geotechnical information could not be checked. Try again." Check your connection and click Analyse Data again.
"Project Settings earthquake zone is required before running this calculation." or "Project Settings soil class is required before running this calculation." Set Earthquake Zone or Soil Class in Project Settings.
"Project Settings earthquake zone must be zone 1, 2, 3 or 4." or "Project Settings soil class must be A, B, C, D or E." Choose a supported value in Project Settings.
"Must be ≤ 3000 mm" or "Must be > 0 mm" under a height. Each retained height must be more than 0 and no more than 3000 mm.
"Minimum is 26°" under Backfill soil friction angle, φb. The backfill angle must be at least 26°, even though Project Settings accepts lower values.
"Minimum is 1.2 m" or "Maximum is 1.5 m" under Pole spacing. Enter a spacing from 1.2 to 1.5 m.
"The saved pole spacing 1 m is outside the allowed range 1.2–1.5 m. Enter a spacing within it before analysing." An older calculation saved with a spacing below 1.2 m still opens as saved. Change the spacing before you click Update Analysis.
A height shows Fail. Check the inputs and analyse again. A closer pole spacing means each pole carries less load. If no combination passes, see When no calculator fits.
"This calculation cannot be accepted or issued. No standard ArchiSuite detail covers this design: No drawing can be produced for this calculation." No height passed, so there is nothing to draw. Get at least one height to pass before you accept.
"Permission denied" when you update or delete. Only team admins and editors can change saved calculations. See Teams and permissions.