Worked example · CALC-013
How to Use the Masonry Foundation Wall Calculator: Worked Example
A step-by-step worked example of the Masonry Foundation Wall calculator, with a screen-recorded video - a reinforced concrete block foundation wall propped by the floor slab and carrying the house above, from Project Settings to the accepted calculation and its documents.
- Author
- ArchiSuite
- Technical review:
- Michael Sheridan
- Reviewed:
- Published:
On this page
This worked example takes one real design through the Masonry Foundation Wall calculator, from Project Settings to an accepted calculation in Project Outputs and the documents it produces. The calculator designs a reinforced concrete block wall that is propped at the top, such as a foundation or basement wall held by a concrete floor slab. It chooses the wall thickness and reinforcement and sizes the footing for ground bearing, including the roof and wall loads that come down onto the wall. Every value below was entered in ArchiSuite, and every result was read from it.
Video tutorial#
The example project#
A reinforced concrete block foundation wall along the back of a house built into a slope, propped at the top by the ground-floor concrete slab. It retains 1.8 m of soil, and carries the house above it: a timber-framed wall with 2.4 m studs and light cladding, and a light roof spanning 8 m with a 0.6 m eave. The soil values come from the project's geotechnical report.
What the example assumes:
The floor slab holds the top of the wall. The typical section in the calculations says: "Concrete floor slab restrains the top; starter bars lapped into the slab". Without that connection, this is not the right calculator: see the Cantilever Masonry Retaining Wall.
The ground behind the wall is level, with the calculator's own "Surcharge 5 kPa" on it. This calculator has no surcharge, slope or wall case to enter.
The soil values come from a geotechnical report. The report in this example is fictional; a real foundation wall needs the real report for its site.
The values are an illustration. They are not defaults for your project.
Step 1: Check the project information#
A retaining wall cannot be analysed until the project's geotechnical information is complete. In the active project's Project Settings, the example uses:
| Project Setting | Value used | Unit | Why it matters here |
|---|---|---|---|
| Earthquake Zone | 2 | Used for the earthquake load case on the wall. | |
| Soil Class | C | The site subsoil class, also used for the earthquake load case. | |
| Geotechnical report details | Demo Geotechnical Ltd, WE-GEO-005 Rev 0 | Company, report reference, title and date. A retaining wall cannot be analysed until all four are filled in with real details (placeholders such as TBC are refused). The report here is fictional, for the example. | |
| Backfill and founding soil properties | φ 30°, γ 18 | kN/m³ | The four soil properties from the report. All four must be filled in; this calculator compares only the backfill values with its form. |
Select Retaining walls under What are you designing? in Project Settings: the form then shows the fields retaining walls need and the Geotechnical Properties section becomes required. This calculator takes its bearing capacity from its own form, not from Project Settings.
Step 2: Open the calculator#
Make the project active. Its name is shown under Active project at the top of every page.
Click All Calculators in the sidebar.
Under Retaining Walls, choose Masonry Foundation Wall.
Click Add Calculation, or New Calculation once the project has one.
Step 3: Enter the wall design inputs#
The form has three sections. The diagram above it shows the wall, the footing and the loads the inputs describe.
These are the exact values entered in the recording:
| Section | Field | Value used | Unit | What it means |
|---|---|---|---|---|
| General Info | Calculation Name | FW1 - Rear foundation wall | - | Names the calculation in Project Outputs and on the drawings and calculations. |
| Geotechnical & Soil Parameters | Footing type | Heel | - | Heel: the footing projects only behind the wall, under the retained soil (Central projects equally both sides). Heel is already selected on a new calculation. |
| Geotechnical & Soil Parameters | Backfill soil friction angle, φb | 30 | ° | The retained soil's friction angle, from the geotechnical report (30 to 36° for this calculator). Matches Project Settings, so the form does not ask you to check it. |
| Geotechnical & Soil Parameters | Backfill soil unit weight, γb | 18 | kN/m³ | The retained soil's unit weight (15 to 20 kN/m³). |
| Geotechnical & Soil Parameters | Geotechnical ultimate bearing capacity, qu | 300 | kPa | The ultimate bearing capacity of the ground under the footing, from your geotechnical report (150 to 300 kPa). Enter the ultimate value, not an allowable one. |
| Wall & Roof Loads | Retained height | 1800 | mm | The height of retained soil, from the top of the footing to the finished ground behind the wall (up to 2500 mm). |
| Wall & Roof Loads | Roof type | Light | - | The weight of the roof that bears on top of the wall: a light roof (for example long-run metal) here. |
| Wall & Roof Loads | Roof span | 8 | m | The span of that roof. Enter 0 where no roof bears on the wall. |
| Wall & Roof Loads | Roof eave | 0.6 | m | The roof's eave overhang beyond the wall. |
| Wall & Roof Loads | Wall cladding type | Light | - | The cladding weight of the timber-framed wall built on top of the foundation wall: light cladding here. |
| Wall & Roof Loads | Stud height | 2.4 | m | The height of that framed wall, from the top of the foundation wall. Enter 0 where there is none. |
A few points from the recording:
A new calculation has one retained height. For a wall whose height changes, make one calculation for each height.
Footing type, Roof type and Wall cladding type already show Heel, Light and Light on a new calculation. Check each one against your design rather than leaving it as it opened.
The roof and wall above are what the foundation wall carries down to its footing. Enter
0for Roof span or Stud height where there is no roof or wall on it.The backfill values match Project Settings, so Analyse Data goes straight on. This calculator compares only the backfill values with Project Settings.
Step 4: Run the calculation#
Click Analyse Data. ArchiSuite first reads the latest saved Project Settings and checks the geotechnical information, then designs the wall. The Summary table appears below the form. If an input is out of range, the form says so beside the field and does not submit.
Step 5: Understand the results#
The Summary#
These are the values ArchiSuite showed for this example:
| Case Index | Hr (mm) | tw (mm) | tf (mm) | hl (mm) | Total Footing (mm) | M* (kNm/m) | Status |
|---|---|---|---|---|---|---|---|
| Case #1 | 1800 | 190 | 300 | 810 | 1000 | 7.620 | Pass |
What the columns mean:
Hr (mm) is the retained height.
tw (mm) is the wall thickness the calculator chose: a 190 mm block wall is tried first, then 240 mm.
tf (mm) is the footing thickness, which is always 300 mm.
hl (mm) is the heel: how far the footing projects behind the wall, under the soil. With a Heel footing there is no toe, so the Total Footing is the wall plus the heel.
*M\ (kNm/m)** is the design bending moment in the wall, per metre of wall.
Status must show Pass before you can accept.
Reinforcement#
The Summary does not show the reinforcement: it is in the Structural Calculations and on the drawings. The calculations' design summary gives, for wall H1, the retained height (m), block (mm), vertical bars, horizontal bars, footing thickness, toe and heel (mm):
"H1 1.8 190 HD12 @ 400 HD12 @ 600 300 0 810"
The loads from the house above#
The roof and wall on top of the foundation wall press it down onto its footing. The calculations take the roof width carried by the wall as half the 8 m roof span plus the 0.6 m eave ("Aroof =4.60 m"), and add the framed wall's weight, giving "Wextra =2.78 kN/m" from the house above, per metre of wall. This load is part of the bearing and eccentricity checks below.
Strength and stability checks#
The Structural Calculations document lists the governing checks. Utilisation is demand ÷ capacity or limit; a utilisation of 1 or less passes.
| Part | Check | Demand | Capacity or limit | Utilisation |
|---|---|---|---|---|
| H1 | Wall flexure (Earthquake) | 7.62 kN.m/m | 10.59 kN.m/m | 0.72 |
| H1 | Bearing pressure (Earthquake) | 109.7 kPa | 150.0 kPa | 0.73 |
| H1 | Eccentricity (Earthquake) – governs | 0.307 m | 0.333 m | 0.92 |
The document's conclusion:
What the checks show for this wall:
Eccentricity governs (0.92). The footing's ground reaction must stay well inside the footing: the limit of 0.333 m is a third of the 1000 mm footing. The calculator sizes the footing width for the bearing checks, and here the earthquake case governs.
Bearing pressure (0.73) is the ground pressure under the footing against the bearing limit of 150.0 kPa for the 300 kPa ultimate capacity entered.
Wall flexure (0.72) is the block wall bending between the footing and the floor slab, with the HD12 @ 400 vertical bars.
The calculation states what it relies on: "The design relies on this positively connected slab for horizontal restraint; sliding of the footing is not checked." Build the slab connection as the drawings show.
Step 6: Accept and access the documentation#
Check that the row shows Pass, then click Accept in the Summary header. ArchiSuite shows:
Open Project Outputs from the sidebar. The calculation is listed under Accepted calculator outputs included with its status.
What you can see and download, and when:
On screen. The Summary, with the wall, footing and status, is in the calculator itself as soon as you analyse.
The document packs. Project Outputs offers three PDFs: the Project Summary, the Structural Calculations (the design basis, the earth pressures, the wall design, the loads from above and the bearing checks) and the Structural Drawings. They download once every accepted output is paid.
Documents that wait for review. Where an Engineering Review is included (it always is for an account without a Licensed Building Practitioner number), the downloads also wait until ArchiSuite has reviewed the documents and released them for issue. See Pay and download your documents.
Once the review is released, the panel says so and every download opens.
The video ends with a quick look through the documents this example produced, as issued: the Project Summary; the PS1 Producer Statement - Design and its Schedule, shown unsigned with the signatory withheld; the B2 durability letter and the Letter of Limited Review; every page of the Structural Calculations; and every sheet of the Structural Drawings. The typical section in the calculations also shows the "Free-draining backfill in geotextile" and the "Perforated drain" behind the wall.
Common mistakes#
Incomplete geotechnical information. Geotechnical information required opens and nothing is analysed. Complete every field of Geotechnical Properties in Project Settings, including the founding values, click Update Project, and analyse again. See Project settings missing.
A backfill friction angle below 30°. Project Settings accepts lower values, but this calculator needs 30° to 36°, and a unit weight of 15 to 20 kN/m³.
An allowable bearing capacity. Enter the geotechnical ultimate bearing capacity (150 to 300 kPa), not an allowable value.
No slab propping the top. If the top of the wall is free, use the Cantilever Masonry Retaining Wall instead.
Leaving out the house above. The roof and framed wall on top add load to the footing. Enter them as they are; use
0only where there is no roof or wall.A failing wall. Accept is refused until the row shows Pass. See When no calculator fits.
The same name twice. Each calculation in a project needs its own name. Change the Calculation Name.
Related guides#
Masonry Foundation Wall: every input, result and refusal of this calculator.
Open the calculator from All Calculators → Retaining Walls (signed in).
The inputs explained: Retained height, Footing type, Backfill soil friction angle, Soil unit weight, Geotechnical Ultimate Bearing Capacity, Roof Type and Wall Cladding Weight.
The other retaining wall worked examples: Cantilever Masonry Retaining Wall and Timber Pole Retaining Wall.
Project Settings, Check and accept results and Pay and download your documents.
Engineering note#
Recorded with CALC-013 Masonry Foundation Wall version 3.4.0 on 2026-11-24.
Video transcript#
0:07 The project Worked Example - Masonry Foundation Wall is active. In Project Settings, Retaining walls is selected, the Earthquake Zone is 2 and the Soil Class is C, and the Geotechnical Properties are complete: the report details and the backfill and founding soil properties, φ 30 degrees and 18 kN/m³.
0:23 Under All Calculators, in Retaining Walls, open Masonry Foundation Wall, then Add Calculation. It designs a reinforced concrete block wall propped at the top, such as a foundation or basement wall supported by the floor slab, for one retained height.
0:33 The calculation is named FW1 - Rear foundation wall. In Geotechnical & Soil Parameters, the footing type is Heel, the backfill soil is φ 30 degrees and 18 kN/m³, as in Project Settings, and the geotechnical ultimate bearing capacity is 300 kPa.
0:52 In Wall & Roof Loads, the retained height is 1800 mm. A light roof spanning 8 m with a 0.6 m eave bears on the wall, and a light-clad framed wall with 2.4 m studs stands on top of it. These loads come down onto the footing.
1:11 Analyse Data runs the calculation. When it finishes, the Summary shows the designed wall.
1:19 The wall passes. The calculator chose the wall thickness tw, sized the heel hl and gives the footing thickness tf, the total footing width and the design bending moment M* in the wall. The vertical reinforcement is in the calculations and on the drawings.
1:38 Accept adds the calculation to Project Outputs.
1:42 Project Outputs lists FW1 - Rear foundation wall as an accepted output. The Structural Calculations and Structural Drawings, with the full checks and the foundation details, download from here once the outputs are paid and, where Engineering Review is included, reviewed and released. Prices are hidden in this video.
1:55 After payment and Engineering Review (not shown), Project Outputs shows the document packs ready to download. A quick look through what they contain: the Project Summary, with the project and every accepted calculation; the PS1 Producer Statement - Design and its Schedule, shown here unsigned with the signatory withheld; the B2 durability letter and the Letter of Limited Review; the Structural Calculations; and the Structural Drawings.