Calculator guide · CALC-013

Masonry Foundation Wall

Design a reinforced concrete block foundation or basement wall propped at the top, for one retained height up to 2.5 m, including roof and wall loads on the footing.

Video: a worked example

One real design taken through this calculator, from Project Settings to the issued documents. Read the worked example and transcript
On this page

The Masonry Foundation Wall calculator designs a reinforced concrete block wall that is propped at the top, such as a foundation or basement wall supported by a concrete floor slab. It chooses the wall thickness and vertical reinforcement, and sizes the footing width for ground bearing. The bearing check includes roof and wall loads that come down onto the wall.

Masonry Foundation Wall · CALC-013

One calculation covers up to five wall heights, including roof and wall-above loads in the footing bearing check.

Use it when

  • A concrete floor slab provides support at the top of the wall.
  • Retained heights up to 2.5 m, with level ground behind.
  • A fixed 5 kPa surcharge suits the site.
  • Importance Level 2 buildings.

Results

  • Block thickness and vertical reinforcement.
  • Footing width for ground bearing.
  • Wall and footing drawing schedules.

Limits

  • The propping slab and its connection require separate design.
  • No floor loads, line loads or groundwater pressure.
  • Footing bending, footing shear and starter-bar anchorage are not checked.
  • The connected slab provides the horizontal restraint; footing sliding is not checked.

Before you start#

This calculator reads these values from the active project's Project Settings:

  • Earthquake Zone and Soil Class. These are used for the earthquake load case. If either one is blank or not a supported value, the calculation is refused.

  • The Geotechnical Properties section. Fill in all four report details (Geotechnical Engineering Company Name, Report Reference / Revision, Report Title, Report Date) and all four soil properties (Backfill soil friction angle, φb, Backfill soil unit weight, γb, Founding soil friction angle, φf, Founding soil unit weight, γf). Save with Update Project. A retaining wall cannot be analysed until every one of these is filled in, even though this calculator compares only the backfill values.

You enter the geotechnical ultimate bearing capacity on this calculator's own form. It does not use the project's Geotechnical Ultimate Bearing Capacity. If the two values differ, a note under the field shows both, so you can check the one you entered.

Project Settings accepts soil friction angles from 20° and unit weights from 14 kN/m³. This calculator is stricter: it needs a backfill friction angle from 30° to 36° and a unit weight from 15 to 20 kN/m³.

Have these ready from the drawings and the geotechnical report:

  • The retained height, in mm (up to 2500 mm).

  • Whether the footing can project in front of the wall as well as behind it.

  • The backfill soil friction angle and unit weight, and the geotechnical ultimate bearing capacity.

  • Any roof that bears on top of the wall (roof type, span and eave), and any wall framing built on top of it (cladding type and stud height).

Step by step#

  1. In the sidebar, click All Calculators. Choose the Retaining Walls tab, then the Masonry Foundation Wall card.

  2. On the Propped Wall Calculations page, click New Calculation. If there are no calculations yet, click Add Calculation.

  3. In General Info, enter a Calculation Name (for example Foundation Wall 1).

  4. In Geotechnical & Soil Parameters, choose the Footing type (Heel or Central). Then enter Backfill soil friction angle, φb, Backfill soil unit weight, γb and Geotechnical ultimate bearing capacity, qu.

  5. In Wall & Roof Loads, enter the Retained height in mm. Choose the Roof type and enter Roof span and Roof eave. Choose the Wall cladding type and enter the Stud height. Enter 0 for Roof span, Roof eave or Stud height where they do not apply.

  6. Click Analyse Data. ArchiSuite first reads the latest saved Project Settings:

    • If the geotechnical information is incomplete, Geotechnical information required opens and nothing is analysed. Click Close, complete Project Settings, then come back and click Analyse Data again. Your form values are kept.

    • If your soil inputs differ from the project's backfill soil properties, Check geotechnical values opens. Click Review inputs to go back and change them. Or click Continue to analyse with the values exactly as you entered them.

  7. The Summary table appears below the form. Check that the row shows Pass.

  8. Click Accept. You will see "Calculation accepted successfully!", the button changes to Accepted, and the calculation is added to Project Outputs.

A new calculation has one retained height

To change a saved calculation, open it from the list. Edit the inputs and click Update Analysis.

The inputs#

Geotechnical & Soil Parameters. Footing type sets the footing shape. Heel projects only behind the wall, under the retained soil. Central projects equally in front of and behind the wall. Backfill soil friction angle, φb and Backfill soil unit weight, γb are the friction angle and unit weight of the soil retained behind the wall. Geotechnical ultimate bearing capacity, qu is the geotechnical ultimate bearing capacity of the ground under the footing, from 150 to 300 kPa. Enter the ultimate value, not an allowable value. If it differs from the project's value, a note under the field shows both. The note does not stop the analysis.

Wall & Roof Loads. Retained height is the height of retained soil, from the top of the footing to the finished ground behind the wall, in mm. Roof type, Roof span and Roof eave describe any roof that bears on top of the wall. The model view marks the roof span with the letter I. Wall cladding type is the cladding weight of any wall built on top of the retaining wall. Stud height is the height of that wall, measured from the top of the retaining wall. These loads are used in the footing bearing check.

There is no wall case to choose on this calculator, and no surcharge or backfill slope to enter. The calculator always applies a 5 kPa surcharge on level ground behind the wall. The arrows marked "Surcharge" on the diagram show it.

  • Footing ModeOptional

    heel · central

  • Soil friction angle (ϕ)Required

    °

  • Soil unit weight (gamma)Required

    15 to 20 kN/m³

    If not: “Maximum value is 20 kN/m³”

  • Allowable bearing capacity (kPa)Required

    150 to 300 kPa

    If not: “Maximum value is 300 kPa”

  • Retained height H (mm)Required

    Retained heights

    more than 0 and up to 2500 mm

    If not: “Must be ≤ 2500 mm”

  • Roof TypeRequired

    Retained heights

    As shown on the form

  • Roof Span (m)Optional

    Retained heights

    m

  • Roof Eave (m)Optional

    Retained heights

    m

  • Wall TypeRequired

    Retained heights

    As shown on the form

  • Wall Extra Height (m)Optional

    Retained heights

    m

Read from Masonry Foundation Wall (CALC-013, version 3.4.0) as it runs today. The form may also show its own limit beside an input.

Worked example#

This is a representative example taken from ArchiSuite's own tests. It is not a design for your site.

Project Settings: Earthquake Zone 2 and Soil Class C. The geotechnical report details are complete, with all four soil properties set to φ 30° and γ 18 kN/m³.

Inputs: Footing type Heel; Backfill soil friction angle, φb 30°; Backfill soil unit weight, γb 18 kN/m³; Geotechnical ultimate bearing capacity, qu 200 kPa; Retained height 1500 mm; Roof type Light; Roof span 6 m; Roof eave 0.6 m; Wall cladding type Light; Stud height 0 m.

Because the backfill values match Project Settings, the analysis runs without a prompt. The Summary shows Case #1 with Hr (mm) 1500, tw (mm) 190, tf (mm) 300, hl (mm) 660, Total Footing (mm) 850, *M\ (kNm/m) 4.523 and Pass**.

Results#

Check the row shows Pass before you accept

The Summary table shows:

  • Case Index: Case #1 (and further cases on older multi-height records).

  • Hr (mm): the retained height.

  • tw (mm): the wall thickness. The calculator tries a 190 mm wall first, then 240 mm.

  • tf (mm): the footing thickness, which is always 300 mm.

  • hl (mm): the heel length. With a Central footing, the toe is the same length as the heel.

  • Total Footing (mm): the total footing width.

  • *M\ (kNm/m)**: the design bending moment in the wall.

  • Status: Pass or Fail.

The vertical reinforcement is given in the calculations and on the drawings.

After you accept, the calculations, project summary and drawings are prepared from Project Outputs. See Pay for and download your documents.

Limitations#

  • One retained height per new calculation, more than 0 mm and no more than 2500 mm.

  • Backfill soil friction angle, φb from 30° to 36°, Backfill soil unit weight, γb from 15 to 20 kN/m³ and Geotechnical ultimate bearing capacity, qu from 150 to 300 kPa.

  • The surcharge is fixed at 5 kPa, and the backfill is level. There are no inputs for floor loads, line loads or groundwater pressure.

  • The wall thickness is 190 mm or 240 mm, and the footing is 300 mm thick. There is no shear key and no toe-only footing.

  • Every retained-height case must pass before the calculation can be accepted.

Common errors and how to fix them#

  • Geotechnical information required: "Complete the geotechnical report details and soil properties in Project Settings before analysing this retaining wall." Fill in every field in the Geotechnical Properties section of Project Settings, including the founding values, save, and analyse again. See Project Settings missing.

  • Check geotechnical values: "These inputs differ from the project geotechnical properties. Check they are suitable before continuing." Click Review inputs and correct the values. Or, if the different values are intended, click Continue.

  • "Project Settings could not be loaded, so the geotechnical information could not be checked. Try again." Check your connection and click Analyse Data again.

  • "Project Settings earthquake zone is required before running this calculation." or "Project Settings soil class is required before running this calculation." Set Earthquake Zone or Soil Class in Project Settings.

  • "Minimum is 30°" under Backfill soil friction angle, φb. This calculator needs at least 30°.

  • "Must be ≤ 2500 mm" under Retained height. The retained height must be no more than 2500 mm.

  • "Minimum is 150 kPa" or "Maximum is 300 kPa" under Geotechnical ultimate bearing capacity, qu. Enter a value from 150 to 300 kPa.

  • The row shows Fail. The calculator could not find a wall and footing that pass. Check the inputs. For example, check that the bearing capacity is the ultimate value. If no combination passes, see When no calculator fits.

  • "All retained-height cases must pass before this calculation can be accepted". Every case must show Pass before you click Accept.

  • "Permission denied" when you update or delete. Only team admins and editors can change saved calculations. See Teams and permissions.

  • "This calculation has been accepted and paid for, so it cannot be changed. Use Revise Calculation on Project Outputs to make a revised version." See Revise an accepted calculation.

Worked example

Was this helpful?

How-toProject SettingsEvery field on the Project Settings page - what it means, the accepted options and limits, which calculators use it, and what happens to existing calculations when you change it.Read TroubleshootingProject Settings Missing or Out of RangeFix messages such as "Roof Pitch is missing or out of range…" or "Project Settings … is required before running this calculation" by completing Project Settings.Read TroubleshootingWhy an Input Is RefusedWhat the red messages under an input and the error toasts after Analyse mean, grouped by cause, with the fix for each.Read How-toCheck and Accept ResultsHow to read a calculator's results, choose a passing member, and press Accept so the calculation moves into Project Outputs.Read How-toPay and Download Your DocumentsPay for accepted calculations on Project Outputs, or send the property owner a payment link, then download the Project Summary, Calculations and Drawings.Read Calculator guideCantilever Masonry Retaining WallDesign a reinforced concrete block cantilever retaining wall on a strip footing for up to five retained heights, with the toe, heel and shear key sized for you.Read Calculator guideTimber Pole Retaining Wall (superseded)Design a timber pole retaining wall for up to five retained heights. Get pole sizes, hole diameters, embedment depths and timber rail options for each height.Read How-toWhen no calculator fitsWhat to do when your design is outside every calculator - submit a design request to ArchiSuite, contact the team, or suggest a calculator through Feedback & Ideas.Read