Worked example · CALC-010
How to Use the Square Pad Foundation Calculator: Worked Example
A step-by-step worked example of the Square Pad Foundation calculator, with a screen-recorded video - a concrete pad under a verandah post, from Project Settings to the accepted calculation and its documents.
- Author
- ArchiSuite
- Technical review:
- Michael Sheridan
- Reviewed:
- Published:
On this page
This worked example takes one real design through the Square Pad Foundation calculator, from Project Settings to an accepted calculation in Project Outputs and the documents it produces. The calculator sizes a square concrete pad under a post or column from the post's reactions, and gives its depth and reinforcement. One calculation can hold up to five pads. Every value below was entered in ArchiSuite, and every result was read from it.
Video tutorial#
The example project#
A square concrete pad under a verandah post. The post's reactions come from the calculation of the beam it supports: 18 kN down for 1.35G, 30 kN down for 1.2G + 1.5Q, 24 kN down for 1.2G + W + 0.4Q, and 6 kN of uplift for 0.9G + Wu. The ground is good ground, 300 kPa.
What the example assumes:
The post's reactions come from another calculation, such as the beam the post holds up. The pad calculator does not work out the loads: it takes the reaction for each of four load combinations.
Signs: a downward reaction is negative and uplift is positive, in kN. The form refuses a downward load entered as positive.
The values are an illustration. They are not defaults for your project.
Step 1: Check the project information#
The foundation calculators read one value from the active project's Project Settings:
| Project Setting | Value used | Unit | Why it matters here |
|---|---|---|---|
| Geotechnical Ultimate Bearing Capacity | 300 | kPa | The ground's ultimate bearing capacity. The pad is sized so the ground pressure stays within it. |
The only Project Setting the foundation calculators read. Select Foundations under What are you designing? in Project Settings to show it. Without it the calculation is refused when you click Analyse Data.
Step 2: Open the calculator#
Make the project active. Its name is shown under Active project at the top of every page.
Click All Calculators in the sidebar.
Under Foundations, choose Square Pad Foundation.
Click Add Square Pad Foundation, or New Square Pad Foundation once the project has one.
Step 3: Enter the pad and its loads#
Above the form, the arrangement drawing shows the pad in section and plan with the post on it, and follows your inputs.
These are the exact values entered in the recording:
| Section | Field | Value used | Unit | What it means |
|---|---|---|---|---|
| General Info | Calculation Name | PD1 - Verandah post pad | - | Names the calculation in Project Outputs and on the drawings and calculations. |
| Foundation Pads | Pad name / reference | P1 | - | The pad's mark on the drawings. |
| Foundation Pads | 1.35G | -18 | kN | The post's reaction for the dead-load-only combination. Downward reactions are negative. |
| Foundation Pads | 1.2G + 1.5Q | -30 | kN | The reaction for dead plus live load, usually the largest downward load. |
| Foundation Pads | 1.2G + W + 0.4Q | -24 | kN | The reaction for dead plus wind (down) with the combination share of live load. |
| Foundation Pads | 0.9G + Wu | 6 | kN | The uplift reaction for wind uplift against 90% of the dead load. Uplift is positive. |
A few points from the recording:
A new calculation starts with one pad, P1. Click + Add Pad for more, up to five.
Enter the reaction for each combination. 1.2G + 1.5Q is usually the largest downward load; 0.9G + Wu is the uplift, which can be the one that sizes the pad.
Step 4: Run the calculation#
Click Analyse Data. ArchiSuite reads the bearing capacity from Project Settings and designs each pad. The Summary appears below the form. If an input is out of range, the form says so beside the field and does not submit.
Step 5: Understand the results#
The summary#
These are the values ArchiSuite showed for this example:
| Pad | Pad Size | Status |
|---|---|---|
| P1 | 1,000 x 1,000 mm | PASS |
The summary gives each pad's plan size and status. Its depth and reinforcement are in the calculations and on the drawing:
| Result | Value |
|---|---|
| Pad depth | 300.0 mm |
| Effective depth | 225.0 mm |
| Reinforcement | HD12 @ 250 mm e/w, top and bottom |
The checks#
The Structural Calculations check the pad for ground bearing, punching shear, beam shear, bending, minimum reinforcement and uplift. Utilisation is demand ÷ capacity or limit; a utilisation of 1 or less passes.
| Part | Check | Demand | Capacity or limit | Utilisation |
|---|---|---|---|---|
| Pad P1 | Ground bearing (G; ψcQ; Ws) | 27.1 kPa | 100.0 kPa | 0.27 |
| Pad P1 | Punching shear (1.2G; 1.5Q) | 0.182 MPa | 1.571 MPa | 0.12 |
| Pad P1 | Beam shear (1.2G; 1.5Q) | 0.114 MPa | 0.800 MPa | 0.14 |
| Pad P1 | Bending (1.2G; 1.5Q) | 4.83 kNm | 42.24 kNm | 0.11 |
| Pad P1 | Minimum reinforcement – governs | 420 mm²/m | 452 mm²/m | 0.93 |
| Pad P1 | Uplift | 6.00 kN | 6.48 kN | 0.93 |
The document's conclusion:
What the checks show for this pad:
Bearing is not what sizes it. The ground pressure is at 0.27 of its limit, and the punching, shear and bending checks are lower still.
Uplift does. The 6 kN of uplift is "Resisted by the weight of the pad." A 1,000 mm square pad 300 mm deep gives 6.48 kN against it (0.93), so a smaller pad would lift.
The pad then needs the minimum reinforcement for its depth (0.93): HD12 bars each way, top and bottom.
Step 6: Accept and access the documentation#
Check that every pad shows PASS, then click Accept in the Summary header. ArchiSuite shows:
Open Project Outputs from the sidebar. The calculation is listed under Accepted calculator outputs included with its status.
What you can see and download, and when:
On screen. The arrangement drawing and the Summary are in the calculator itself as soon as you analyse.
The document packs. Project Outputs offers three PDFs: the Project Summary, the Structural Calculations (the design basis and each pad's loads and checks) and the Structural Drawings. They download once every accepted output is paid.
Documents that wait for review. Where an Engineering Review is included (it always is for an account without a Licensed Building Practitioner number), the downloads also wait until ArchiSuite has reviewed the documents and released them for issue. See Pay and download your documents.
Once the review is released, the panel says so and every download opens.
The video ends with a quick look through the documents this example produced, as issued: the Project Summary; the PS1 Producer Statement - Design and its Schedule, shown unsigned with the signatory withheld; the B2 durability letter and the Letter of Limited Review; every page of the Structural Calculations; and every sheet of the Structural Drawings.
Common mistakes#
Downward loads entered as positive. Downward reactions are negative and uplift is positive; the form says "Must be strictly negative (< 0)" or "Must be strictly positive (> 0)" otherwise.
Leaving out the uplift. Enter the 0.9G + Wu reaction from the beam's calculation: it can size the pad.
Factored and unfactored loads mixed up. Each box is the reaction for the combination named on it.
No bearing capacity in Project Settings. The calculation is refused. Select Foundations under What are you designing? in Project Settings, enter the Geotechnical Ultimate Bearing Capacity and click Update Project. See Project settings missing.
The same name twice. Each calculation in a project needs its own name. Change the Calculation Name.
Related guides#
Square Pad Foundation: every input, result and refusal of this calculator.
Open the calculator from All Calculators → Foundations (signed in).
The inputs explained: Square pad, Pad name, Load notation, 1.35G, 1.2G + 1.5Q, 1.2G + W + ψcQ, 0.9G + Wu and Geotechnical Ultimate Bearing Capacity.
The other foundation worked examples: TC1 Single Storey Foundation, TC2 Single Storey Foundation and Raft Slab Reduced Bearing Single Storey.
Project Settings, Check and accept results and Pay and download your documents.
Engineering note#
Recorded with CALC-010 Square Pad Foundation version 1.17.0 on 2026-11-24.
Video transcript#
0:07 The project Worked Example - Square Pad Foundation is active. Under What are you designing?, Foundations is selected, and the calculator reads one Project Setting: the Geotechnical Ultimate Bearing Capacity, 300 kPa, good ground.
0:18 Under All Calculators, in Foundations, open Square Pad Foundation, then Add Square Pad Foundation. It sizes a square concrete pad under a post or column, from the post's reactions.
0:36 The calculation is named PD1 - Verandah post pad. In Foundation Pads, pad P1 takes the post's reactions for the four load combinations, from the calculation of the beam it supports: downward loads are negative and uplift is positive, in kN.
0:58 Back at the top of the page, the arrangement drawing has followed the inputs.
1:05 Analyse Data runs the calculation. When it finishes, the summary appears below the form.
1:13 Pad P1 is 1,000 x 1,000 mm, and passes. Its depth and reinforcement are in the calculations.
1:21 Accept adds the calculation to Project Outputs.
1:26 Project Outputs lists PD1 - Verandah post pad as an accepted output. The Structural Calculations and Structural Drawings, with the full checks and the foundation details, download from here once the outputs are paid and, where Engineering Review is included, reviewed and released. Prices are hidden in this video.
1:38 After payment and Engineering Review (not shown), Project Outputs shows the document packs ready to download. A quick look through what they contain: the Project Summary, with the project and every accepted calculation; the PS1 Producer Statement - Design and its Schedule, shown here unsigned with the signatory withheld; the B2 durability letter and the Letter of Limited Review; the Structural Calculations; and the Structural Drawings.