Calculator guide · CALC-003
TC1 Single Storey Foundation
Size the ribs of a pod-and-rib slab for a single-storey house, and square pads for up to five point loads, using the bearing capacity set in Project Settings.
Video: a worked example
On this page
TC1 Single Storey Foundation sizes the concrete ribs of a pod-and-rib slab for a single-storey house. It finds the rib width that keeps the ground pressure within the bearing capacity in your Project Settings for three ribs: the external load-bearing rib, the governing internal load-bearing rib and the internal non-load-bearing rib. It can also design a square concrete pad under each of up to five point loads.
TC1 Single Storey Foundation · CALC-003
Size foundation ribs for a single-storey house, with pads for up to five point loads.
Use it when
- A single-storey house on a pod-and-rib slab.
- TC1 sites, or good ground confirmed by your geotechnical assessment.
Results
- External and internal foundation rib widths.
- Pad sizes and reinforcement for entered point loads.
- Foundation and pad drawing schedules.
Limits
- Single storey only.
- General rib reinforcement is not designed.
- No TC3, pile foundations or earthquake reactions at pads.
Before you start#
Set the bearing capacity in Project Settings. Open Project Settings and enter Geotechnical Ultimate Bearing Capacity (150 to 300 kPa), then click Update Project. This is the only Project Settings value this calculator reads, and you cannot type it on the form. If Foundations is the only box ticked under What are you designing?, the Site Parameters section asks only for this value.
Use your own ground information. ArchiSuite does not work out your land's technical category (TC1 or TC2), whether it is good ground, or its bearing capacity. The calculator does not check the technical category either. The Project Settings hint suggests 300 kPa for good ground, but only use 300 kPa if your designer or geotechnical engineer has confirmed it for your site.
Optional: add the geotechnical report details under Geotechnical Properties (optional) in Project Settings. They are printed on the drawings.
Measure from your plans:
For the external wall line: the roof loaded dimension, or the roof span and eave / overhang. You also need the roof type, the wall height and the cladding type.
For each internal load-bearing wall line: the roof loaded dimension it carries, the roof type, the wall height and the cladding type.
For each post, girder truss or beam that bears on the slab: its four factored reactions in kN, taken from that member's own calculation.
Step by step#
Click All Calculators in the sidebar, choose the Foundations tab and click TC1 Single Storey Foundation.
Click New TC1 Single Storey Foundation. If the list is empty, the button reads Add TC1 Single Storey Foundation.
Under General Info, enter a Calculation Name. You must enter one.
Under External Load-Bearing Wall Foundations, fill in Roof (External):
Enter Roof loaded dimension (m), or enter both Roof span (m) and Eave / overhang (m).
Choose Roof type.
Fill in Wall (External): enter Wall height (m) and choose Wall cladding type.
Optional: under Internal Load-Bearing Wall Foundations (Optional), click Add Internal Foundation (or Add Case once one exists). Add one case for each internal load-bearing wall line, up to five. In each Case:
Under Roof (Internal), enter Roof loaded dimension (m) and choose Roof type.
Under Wall (Internal), enter Wall height (m) and choose Wall cladding type.
Use the bin icon to remove a case.
Optional: under Point Loads (Optional), click Add Point Load for each post or beam bearing on the slab, up to five. Fill in:
Name / reference
On thickening?
1.35G (kN)
1.2G + 1.5Q (kN)
1.2G + W + ψcQ (kN)
0.9G + W uplift (kN)
Click Analyse Data. The button shows Processing... while it runs. The results then appear under Foundation Category Summary.
Check each row's status (see Results below). When you are happy, click Accept. You see "Calculation accepted successfully!" and the button changes to Accepted. The calculation is now in your Project Outputs.
To change a saved calculation, open it from the list by clicking its row (or Edit Calculation in its menu). Change the inputs and click Update Analysis.
The inputs#
Roof (External) and Wall (External)#
These describe the external wall line. Enter the roof in one way only. The form's note says: "Enter either the roof loaded dimension, or both the roof span and eave / overhang. Use the largest roof loaded dimension supported by an external wall."
Roof loaded dimension (m) is the width of roof whose weight comes onto the wall line (Roof loaded dimension).
Roof span (m) is the full span of the roof framing (Roof span). Eave / overhang (m) is the overhang past the wall.
If you use the span, the calculator takes the loaded dimension as half the span plus the eave.
Once you type in one way, the other boxes are cleared and greyed out ("Not used - loaded dimension entered" or "Not used - span/eaves entered").
Roof type is Light or Heavy (Roof type).
Wall height (m) is up to 4.8 m (Wall height).
Wall cladding type is Light, Medium or Heavy (Wall cladding weight). The grey "Medium" in the box is only a placeholder, so pick a value from the list.
Internal Load-Bearing Wall Foundations#
Add one case for each internal load-bearing wall line (Internal group). The form's note says: "Enter roof loaded dimension on load-bearing wall." Internal cases take the roof loaded dimension only, not a span. Each case is checked, but the results show one internal row: the governing (widest) case. With no cases, the internal row shows SKIPPED.
The internal non-load-bearing rib is always designed, with no roof or wall load on it. You do not enter anything for it.
Point Loads#
Enter one row for each post, girder truss or beam that bears on the slab (Point loads).
The reactions are factored values taken from that member's own calculation:
1.35G, 1.2G + 1.5Q and 1.2G + W + ψcQ are downward. Enter them as negative numbers.
0.9G + W uplift is the uplift case. Enter zero or a positive number.
Pads: every point load is designed as a square pad.
On thickening? Choose Yes if the load sits over a slab thickening (a deeper strip of concrete in the slab, such as the rib along its outside edge). The calculator then also checks the thickening as an edge beam. That check assumes a thickening 300 mm wide and 305 mm deep. A new point load starts at Yes, so change it to No if the load does not sit over a thickening.
Name / reference is your own label, for example PL1. New rows are named PL1, PL2 and so on.
| Input | Accepted values | Required |
|---|---|---|
| External walls and roof | ||
| Roof loaded dimension, L.D (m)(m) | As shown on the form | No |
| Roof span, Sr (m)(m) | As shown on the form | No |
| Eave / overhang, Se (m)(m) | As shown on the form | No |
| Roof type | As shown on the form | No |
| Wall height (m)(m) | As shown on the form | No |
| Wall type | As shown on the form | No |
| Internal load-bearing ribs | ||
| Roof loaded dimension, L.D (m)(m) | As shown on the form | No |
| Roof span, Sr (m)(m) | As shown on the form | No |
| Eave / overhang, Se (m)(m) | As shown on the form | No |
| Roof type | As shown on the form | No |
| Wall height (m)(m) | As shown on the form | No |
| Wall type | As shown on the form | No |
| Point loads | ||
| On thickening? | As shown on the form | No |
| 1.35G (kN) | As shown on the form | No |
| 1.2G + 1.5Q (kN) | As shown on the form | No |
| 1.2G + W + ψcQ (kN) | As shown on the form | No |
| 0.9G + W uplift (kN) | As shown on the form | No |
- Roof loaded dimension, L.D (m)Optional
External walls and roof
m
- Roof span, Sr (m)Optional
External walls and roof
m
- Eave / overhang, Se (m)Optional
External walls and roof
m
- Roof typeOptional
External walls and roof
As shown on the form
- Wall height (m)Optional
External walls and roof
m
- Wall typeOptional
External walls and roof
As shown on the form
- Roof loaded dimension, L.D (m)Optional
Internal load-bearing ribs
m
- Roof span, Sr (m)Optional
Internal load-bearing ribs
m
- Eave / overhang, Se (m)Optional
Internal load-bearing ribs
m
- Roof typeOptional
Internal load-bearing ribs
As shown on the form
- Wall height (m)Optional
Internal load-bearing ribs
m
- Wall typeOptional
Internal load-bearing ribs
As shown on the form
- On thickening?Optional
Point loads
As shown on the form
- 1.35G (kN)Optional
Point loads
As shown on the form
- 1.2G + 1.5Q (kN)Optional
Point loads
As shown on the form
- 1.2G + W + ψcQ (kN)Optional
Point loads
As shown on the form
- 0.9G + W uplift (kN)Optional
Point loads
As shown on the form
Read from TC1 Single Storey Foundation (CALC-003, version 1.17.0) as it runs today. The form may also show its own limit beside an input.
Worked example#
This is a representative example taken from ArchiSuite's test suite. It is not a design for your site. Project Settings bearing capacity: 250 kPa.
| Section | Input | Value |
|---|---|---|
| Roof (External) | Roof span / Eave / overhang | 7.0 m / 0.45 m |
| Roof (External) | Roof type | Light |
| Wall (External) | Wall height / Wall cladding type | 2.4 m / Light |
| Case 1 | Roof loaded dimension / Roof type | 2.5 m / Heavy |
| Case 1 | Wall height / Wall cladding type | 2.4 m / Light |
| Point Load 1 | Name / On thickening? | PL1 / No |
| Point Load 1 | 1.35G / 1.2G + 1.5Q / 1.2G + W + ψcQ / 0.9G + W uplift | -20 / -25 / -15 / 3 kN |
After Analyse Data, all three rows show PASS:
The external and internal load-bearing ribs pass at the narrowest width the calculator tries, 0.300 m.
The non-load-bearing rib passes at 0.100 m.
Every row has a depth of 0.305 m.
The pad for PL1 is not shown on screen. It is in the PDFs.
Results#
The Foundation Category Summary has one row for each of External Load-Bearing Rib/Wall, Internal Load-Bearing Rib/Wall and Internal Non-Load-Bearing Floor/Rib. Each row has these columns:
Footing Width, B (m): the narrowest width at which all four ground-bearing checks pass. Load-bearing ribs are tried from 0.300 m to 0.600 m, and the non-load-bearing rib from 0.100 m to 0.300 m, in 0.05 m steps.
Footing Depth, D (m): always 0.305 m.
Status:
PASS: a width in the range passed.
FAIL: no width up to the maximum passed. The row shows the last width tried.
SKIPPED: no internal cases were entered.
The calculator sizes rib width only. General rib reinforcement is not sized.
Point-load results are not shown on screen. After paying, you can download:
"TC1 Foundation Structural Calculations Single Storey": the load build-up, load combinations and bearing checks for each rib. The internal heading notes "Critical case displayed only". It also has "Point load checks": each pad's size and bars, or "SED required" (specific engineering design), plus the edge-beam result ("edge beam adequate" or "edge beam not adequate - pad adopted").
The summary PDF: a rib schedule and a "Point load schedule".
The drawings: your rib widths, loading values, bearing capacity and pad schedule. See Pay and download.
Limitations#
Single storey only. Each line is a roof plus one wall. There are no floor or lower-wall inputs. For two storeys, use TC1 Multi Storey Foundation.
Ground bearing only. Ribs are sized for ground bearing, the rib depth is fixed at 305 mm, and rib reinforcement is not designed.
Number of entries. You can enter up to five internal cases and up to five point loads.
Pads:
They are square, from 300 to 3000 mm wide and 300 to 500 mm thick, with HD12, HD16 or HD20 bottom bars.
They are designed for the gravity and wind reactions you enter, and earthquake reactions are taken as zero.
Punching shear assumes a 90 x 90 mm post.
Bearing capacity. The Project Settings bearing capacity must be from 150 to 300 kPa.
Site category. The calculator does not assess the site's technical category, settlement or liquefaction.
Common errors and how to fix them#
"Project Settings geotechnical ultimate bearing capacity is required before running this calculation." Enter Geotechnical Ultimate Bearing Capacity in Project Settings, click Update Project, then click Analyse Data again. See Project settings missing.
"Project Settings geotechnical ultimate bearing capacity must be between 150 and 300 kPa." Correct the value in Project Settings.
"Calculation name is required": enter a Calculation Name.
"roof_type must be one of: light, heavy." Choose a Roof type for the external roof and for every internal case.
"roof span must be a number." You have not entered the roof. Enter Roof loaded dimension (m), or both Roof span (m) and Eave / overhang (m).
"eave width must be a number." You entered a roof span but no eave. Enter Eave / overhang (m) (0 if there is none), or use the loaded dimension instead.
"upper wall_type must be one of: light, medium, heavy." Choose a Wall cladding type. On this form, "upper wall" means the Wall (External) or Wall (Internal) inputs. A grey "Medium" is not a selection.
"upper wall height must be a number." Enter Wall height (m).
"Enter either the roof loaded dimension or the roof span and eaves width, not both." Clear one of the two ways of entering the roof.
"Allowed range: 0 – 8 m", "Allowed range: 0 – 12 m", "Allowed range: 0 – 2 m", "Allowed range: 0 – 4.8 m": the value is outside what the calculator accepts for that box.
"Must be strictly negative (< 0)" on a point load: enter the downward reactions as negative numbers.
"Must be >= 0": the uplift reaction cannot be negative.
"Required": every point-load reaction must be filled in. Remove point loads you do not need with the bin icon.
A FAIL row: check the inputs for that line first, for example the loaded dimension, roof type and cladding type. If they are right, the line is outside what this calculator can design. See When no calculator fits.
"This calculation cannot be accepted or issued. ...": Accept was refused, and the rest of the message gives the reason. See Check and accept results.