Calculator guide · CALC-010
Square Pad Foundation
Design one to five separate square concrete pad footings under posts or columns from their factored reactions, using the bearing capacity set in Project Settings.
Video: a worked example
On this page
Square Pad Foundation designs one to five separate square concrete pad footings, each under a post or column. For each pad you enter the factored support reactions from the member above. The calculator then finds the smallest square pad that passes these checks against the bearing capacity in your Project Settings:
ground bearing
uplift
punching shear
beam shear
bending
minimum steel
Square Pad Foundation · CALC-010
Design up to five square concrete pad footings using the support reactions from the structure above.
Use it when
- You need separate pads beneath posts or beam supports.
- You have the gravity and wind-uplift reactions for each support.
Results
- Pad width and thickness.
- Reinforcement size and spacing.
- Bearing, uplift and structural checks.
Limits
- Square pads up to 3.0 m wide and 500 mm thick.
- No column base moments or earthquake reactions.
- Punching shear assumes a 90 × 90 mm post.
Before you start#
Set the bearing capacity in Project Settings. Open Project Settings and enter Geotechnical Ultimate Bearing Capacity (150 to 300 kPa), then click Update Project. It is the only Project Settings value this calculator reads, and it is not on the form. If Foundations is the only box ticked under What are you designing?, this is the only site parameter the settings form asks for.
Get the reactions for each support from the calculation of the post, column or beam it carries. You need four factored values in kN:
1.35G
1.2G + 1.5Q
1.2G + W + 0.4Q
0.9G + Wu
Check the signs. On this calculator, downward is negative and uplift is positive. Many beam and portal outputs (ArchiSuite's included) show a downward reaction as positive, so check the sign of each value you copy.
Name each pad to match your foundation plan, for example P1, P2.
Step by step#
Click All Calculators in the sidebar, choose the Foundations tab and click Square Pad Foundation.
Click New Square Pad Foundation (or Add Square Pad Foundation if the list is empty).
Under General Info, enter a Calculation Name.
Under Foundation Pads, fill in Pad 1:
Pad name / reference
1.35G
1.2G + 1.5Q
1.2G + W + 0.4Q
0.9G + Wu
All values are in kN.
Click + Add Pad for each further pad, up to five. At five you see "Maximum 5 pads reached". Click Remove on a pad to delete it. Remove shows only when there is more than one pad.
Click Analyse Data. The results appear in the Summary table.
Check each pad's status, then click Accept. You see "Calculation accepted successfully!", the button changes to Accepted, and the calculation is added to Project Outputs.
To change it later, open it from the list, edit the inputs and click Update Analysis.
The inputs#
Foundation Pads#
The form's note says: "Configure up to 5 foundation pads, defining reference names and load combinations." For more on the pad itself, see Square pad foundation.
Pad name / reference is your own label (Pad name). New pads are named P1, P2 and so on. It has no effect on the engineering result.
1.35G, 1.2G + 1.5Q and 1.2G + W + 0.4Q are downward reactions (1.35G, 1.2G + 1.5Q, 1.2G + W + ψcQ). Enter each as a negative number. The form does not accept zero or a positive value. The 0.4 in the third label is ψc, which is fixed at 0.4.
0.9G + Wu is the wind uplift case (0.9G + W uplift). Enter it as a positive number greater than zero.
These are factored values. See Load notation.
The form has no earthquake or snow combination, and no column base moment.
| Input | Accepted values | Required |
|---|---|---|
| Pads | ||
| Pad name / reference | As shown on the form | No |
| 1.35G | As shown on the form | Yes |
| 1.2G + 1.5Q | As shown on the form | Yes |
| 1.2G + W + 0.4Q | As shown on the form | Yes |
| 0.9G + Wu | As shown on the form | Yes |
- Pad name / referenceOptional
Pads
As shown on the form
- 1.35GRequired
Pads
As shown on the form
- 1.2G + 1.5QRequired
Pads
As shown on the form
- 1.2G + W + 0.4QRequired
Pads
As shown on the form
- 0.9G + WuRequired
Pads
As shown on the form
Read from Square Pad Foundation (CALC-010, version 1.17.0) as it runs today. The form may also show its own limit beside an input.
Worked example#
This is a representative example from ArchiSuite's test suite, not a design for your site. Project Settings bearing capacity: 250 kPa.
| Pad name / reference | 1.35G | 1.2G + 1.5Q | 1.2G + W + 0.4Q | 0.9G + Wu |
|---|---|---|---|---|
| P1 | -80 | -95 | -70 | 10 |
| P2 | -30 | -40 | -25 | 2 |
After Analyse Data, the Summary shows:
P1: Pad Size "1,250 x 1,250 mm", Status PASS
P2: Pad Size "650 x 650 mm", Status PASS
Results#
The Summary table has one row per pad:
Pad: your pad name.
Pad Size: the square size in mm, for example "1,250 x 1,250 mm". If no pad works, it shows "-".
Status: PASS, or "SED required" when no pad in the search range passes. "SED required" means a specific engineering design is needed.
How the size is found:
The calculator starts at 300 mm thick and tries square sizes from 300 to 3000 mm in 50 mm steps.
If none passes at that thickness, it goes thicker in 50 mm steps, up to 500 mm.
For each size it picks the first bar size and spacing that passes, in a fixed order: HD12, then HD16, then HD20, each at 250, 200, 150 and 100 mm spacing each way.
The thickness and reinforcement are not shown in the on-screen table. After paying, you can download:
The calculations PDF: each pad's loads, adopted size, thickness and reinforcement, the bearing table and the other checks.
A Project Summary.
A pad details drawing with a pad schedule. See Pay and download.
Limitations#
Number of pads. Each calculation has one to five pads.
Square pads only. No rectangular, combined, strip or pile footings.
Size range. Pads are 300 to 3000 mm square and 300 to 500 mm thick, with HD12, HD16 or HD20 bars at 100 to 250 mm spacing each way.
Reactions. Only vertical and wind uplift reactions are used. Earthquake reactions and column base moments are taken as zero.
Post size. Punching shear assumes a 90 x 90 mm post.
Uplift value. Each pad needs an uplift value greater than zero.
Bearing capacity. The Project Settings bearing capacity must be from 150 to 300 kPa.
Common errors and how to fix them#
"Project Settings geotechnical ultimate bearing capacity is required before running this calculation." Enter it in Project Settings, click Update Project, and analyse again. See Project settings missing.
"Project Settings geotechnical ultimate bearing capacity must be between 150 and 300 kPa." Correct the value in Project Settings.
"Calculation name is required": enter a Calculation Name.
"Required" under a pad field: every pad needs a name and all four reactions.
"Must be strictly negative (< 0)": enter 1.35G, 1.2G + 1.5Q and 1.2G + W + 0.4Q as negative numbers. If your source shows them as positive, change the sign.
"Must be strictly positive (> 0)": 0.9G + Wu must be greater than zero on this calculator.
"SED required" in the Status column: no square pad up to 3000 mm wide and 500 mm thick passes. Check the reactions and their signs first. If they are right, the support needs a specific design. See When no calculator fits.
"This calculation cannot be accepted or issued. ...": the rest of the message gives the reason. See Check and accept results.