Worked example · CALC-003

How to Use the TC1 Single Storey Foundation Calculator: Worked Example

A step-by-step worked example of the TC1 Single Storey Foundation calculator, with a screen-recorded video - the pod-and-rib slab ribs of a single-storey house on TC1 land, from Project Settings to the accepted calculation and its documents.

Author
ArchiSuite
Technical review:
Michael Sheridan
Reviewed:
Published:
On this page

This worked example takes one real design through the TC1 Single Storey Foundation calculator, from Project Settings to an accepted calculation in Project Outputs and the documents it produces. The calculator sizes the concrete ribs of a pod-and-rib slab for a single-storey house on TC1 land: the external load-bearing rib under the outside walls, any internal load-bearing rib, and the internal non-load-bearing rib. It finds the rib width that keeps the ground pressure within the site's bearing capacity. Every value below was entered in ArchiSuite, and every result was read from it.

Video tutorial#

The whole example, including a quick look at its documents, in about three minutes. Each step is captioned on screen; closed captions (CC) and the transcript at the end of this page give the same steps as text.2:46Read the transcript

The example project#

A single-storey timber-framed house on a pod-and-rib slab, on TC1 land with good ground (300 kPa ultimate bearing capacity). Light roof trusses span 9 m from external wall to external wall, with a 0.6 m eave, on 2.4 m external walls with light weatherboard cladding. There is no internal load-bearing wall and no point load on the slab.

What the example assumes:

  • The site is TC1 land and good ground. For TC2 land, see the TC2 Single Storey Foundation worked example; for ground below 300 kPa, the Raft Slab one.

  • The trusses span the full width of the house, so there is no internal load-bearing wall, and no point load on the slab.

  • The values are an illustration. They are not defaults for your project.

Step 1: Check the project information#

The foundation calculators read one value from the active project's Project Settings:

Project SettingValue usedUnitWhy it matters here
Geotechnical Ultimate Bearing Capacity300kPaThe ground's ultimate bearing capacity, from the site's geotechnical assessment. The ribs are sized so the ground pressure stays within it.

The only Project Setting the foundation calculators read. Select Foundations under What are you designing? in Project Settings to show it. Without it the calculation is refused when you click Analyse Data.

Project Settings: the Geotechnical Ultimate Bearing Capacity

Step 2: Open the calculator#

  1. Make the project active. Its name is shown under Active project at the top of every page.

  2. Click All Calculators in the sidebar.

  3. Under Foundations, choose TC1 Single Storey Foundation.

  4. Click Add TC1 Single Storey Foundation, or New TC1 Single Storey Foundation once the project has one.

All Calculators: Foundations → TC1 Single Storey Foundation

Step 3: Enter the foundation inputs#

Above the form, the arrangement drawing shows a section through the slab: the external rib under the wall, the roof span A (and B where an internal wall divides it), the wall height C and the eave D. The same letters are beside the input labels, and the drawing follows your inputs as you type.

The new calculation, before any inputs

These are the exact values entered in the recording:

SectionFieldValue usedUnitWhat it means
General InfoCalculation NameFD1 - House on TC1 land-Names the calculation in Project Outputs and on the drawings and calculations.
Roof (External)Roof loaded dimension(left blank)mLeft blank: the roof span and eave below give it instead (the calculator takes half the span plus the eave).
Roof (External)Roof span, A or B9mThe span of the roof framing that bears on the external wall: here trusses spanning 9 m from wall to wall. With an internal load-bearing wall it is the larger bay (A or B on the drawing).
Roof (External)Eave / overhang, D0.6mThe eave overhang beyond the external wall.
Roof (External)Roof typeLight-Light roofing (for example long-run metal).
Wall (External)Wall height, C2.4mThe height of the external timber-framed wall on the foundation (up to 4.8 m).
Wall (External)Wall cladding typeLight-The cladding weight of that wall: light weatherboards here.

A few points from the recording:

  • Give the roof one way only: the Roof loaded dimension, or the Roof span and Eave / overhang. With the span, the calculator takes half the span plus the eave as the roof width the external wall carries.

  • The Roof span is the span of the roof framing that bears on the wall. Here the trusses span the whole 9 m width. Where an internal load-bearing wall divides the roof, enter the larger bay.

  • Internal Load-Bearing Wall Foundations and Point Loads are optional. Leave them empty when there is no internal load-bearing wall or point load, as here.

The completed inputs for FD1 - House on TC1 land

Back at the top of the page, the arrangement drawing now shows this house:

The slab section with the roof span, eave and wall height entered

Step 4: Run the calculation#

Click Analyse Data. ArchiSuite reads the bearing capacity from Project Settings and designs the ribs. The Foundation Category Summary appears below the form. If an input is out of range, the form says so beside the field and does not submit.

Step 5: Understand the results#

The summary#

These are the values ArchiSuite showed for this example:

CategoryFooting Width, B (m)Footing Depth, D (m)Status
External Load-Bearing Rib/Wall0.3000.305PASS
Internal Non-Load-Bearing Floor/Rib0.1000.305PASS
Internal Load-Bearing Rib/Wall--SKIPPED
The summary after Analyse Data

What the rows mean:

  • External Load-Bearing Rib/Wall: the rib under the external walls, carrying the roof, the wall and its share of the slab. Footing Width, B is its width and Footing Depth, D its depth.

  • Internal Non-Load-Bearing Floor/Rib: the ribs across the slab that carry the slab and its floor load only. They are always designed.

  • Internal Load-Bearing Rib/Wall shows SKIPPED because no internal case was entered. With an internal load-bearing wall it is designed too.

  • Status must show PASS (or SKIPPED for a row with no inputs) before you can accept.

The checks#

The Structural Calculations work out the load on each rib per metre and check the ground pressure under it. Their design inputs set the limits from the bearing capacity: "Bearing limit, ULS 0.5 of ultimate" and "Bearing limit, SLS 1/3 of ultimate". Utilisation is demand ÷ capacity or limit; a utilisation of 1 or less passes.

PartCheckDemandCapacity or limitUtilisation
External ribGround bearing (G + 0.7Q) – governs25.0 kPa100.0 kPa0.25
Non-load-bearing ribGround bearing (G + 0.7Q) – governs42.4 kPa100.0 kPa0.42

The document's conclusion:

What the checks show for this house:

  • The ground bearing under the service loads (G + 0.7Q) governs both ribs, against the 100.0 kPa limit, a third of the 300 kPa entered.

  • The external rib is at 0.25: the light roof and walls put little pressure on good ground.

  • The non-load-bearing rib is at 0.42: it is narrower, at 100 mm, and carries the slab and its floor load.

Step 6: Accept and access the documentation#

  1. Check that every row shows PASS or SKIPPED, then click Accept in the summary header. ArchiSuite shows:

  1. Open Project Outputs from the sidebar. The calculation is listed under Accepted calculator outputs included with its status.

Project Outputs lists the accepted calculation (prices blurred)

What you can see and download, and when:

  • On screen. The arrangement drawing and the Foundation Category Summary are in the calculator itself as soon as you analyse.

  • The document packs. Project Outputs offers three PDFs: the Project Summary, the Structural Calculations (the design basis, the loads on each rib and the ground bearing checks) and the Structural Drawings. They download once every accepted output is paid.

  • Documents that wait for review. Where an Engineering Review is included (it always is for an account without a Licensed Building Practitioner number), the downloads also wait until ArchiSuite has reviewed the documents and released them for issue. See Pay and download your documents.

The document packs open after payment and, where included, Engineering Review

Once the review is released, the panel says so and every download opens.

After payment and Engineering Review: the documents are released for issue

The video ends with a quick look through the documents this example produced, as issued: the Project Summary; the PS1 Producer Statement - Design and its Schedule, shown unsigned with the signatory withheld; the B2 durability letter and the Letter of Limited Review; every page of the Structural Calculations; and every sheet of the Structural Drawings.

Common mistakes#

  • No bearing capacity in Project Settings. The calculation is refused. Select Foundations under What are you designing? in Project Settings, enter the Geotechnical Ultimate Bearing Capacity and click Update Project. See Project settings missing.

  • Entering the roof twice. Enter the roof loaded dimension, or the roof span and eave, not both.

  • The whole roof width as the span where an internal wall supports the roof. Enter the larger bay, and add the internal wall as an internal case.

  • Leaving out an internal load-bearing wall. If one carries the roof, add it under Internal Load-Bearing Wall Foundations; otherwise its rib is not designed.

  • The wrong technical category. This calculator is for TC1 land. Use the TC2 calculator on TC2 land, and the raft slab where the bearing capacity is below 300 kPa.

  • The same name twice. Each calculation in a project needs its own name. Change the Calculation Name.

Engineering note#

Recorded with CALC-003 TC1 Single Storey Foundation version 1.17.0 on 2026-11-24.

Video transcript#

  • 0:07 The project Worked Example - TC1 Single Storey Foundation is active. Under What are you designing?, Foundations is selected, and the calculator reads one Project Setting: the Geotechnical Ultimate Bearing Capacity, 300 kPa, good ground as NZS 3604 defines it.

  • 0:18 Under All Calculators, in Foundations, open TC1 Single Storey Foundation, then Add TC1 Single Storey Foundation. It sizes the concrete ribs of a pod-and-rib slab for a single-storey house on TC1 land.

  • 0:33 The calculation is named FD1 - House on TC1 land.

  • 0:39 In External Load-Bearing Wall Foundations, the roof is entered by its span instead of its loaded dimension: light roof trusses spanning 9 m with a 0.6 m eave, on 2.4 m external walls with light cladding. There is no internal load-bearing wall, so the optional internal cases are left empty.

  • 0:59 Back at the top of the page, the arrangement drawing has followed the inputs.

  • 1:06 Analyse Data runs the calculation. When it finishes, the summary appears below the form.

  • 1:14 The external load-bearing rib is 0.300 m wide and 0.305 m deep, and passes. The internal non-load-bearing rib is designed too; the internal load-bearing row is SKIPPED, because no internal case was entered.

  • 1:26 Accept adds the calculation to Project Outputs.

  • 1:30 Project Outputs lists FD1 - House on TC1 land as an accepted output. The Structural Calculations and Structural Drawings, with the full checks and the foundation details, download from here once the outputs are paid and, where Engineering Review is included, reviewed and released. Prices are hidden in this video.

  • 1:43 After payment and Engineering Review (not shown), Project Outputs shows the document packs ready to download. A quick look through what they contain: the Project Summary, with the project and every accepted calculation; the PS1 Producer Statement - Design and its Schedule, shown here unsigned with the signatory withheld; the B2 durability letter and the Letter of Limited Review; the Structural Calculations; and the Structural Drawings.

Was this helpful?

Calculator guideTC1 Single Storey FoundationSize the ribs of a pod-and-rib slab for a single-storey house, and square pads for up to five point loads, using the bearing capacity set in Project Settings.Read Worked exampleHow to Use the TC2 Single Storey Foundation Calculator: Worked ExampleA step-by-step worked example of the TC2 Single Storey Foundation calculator, with a screen-recorded video - the pod-and-rib slab ribs of a single-storey house on TC2 land, from Project Settings to the accepted calculation and its documents.Read Worked exampleHow to Use the Raft Slab Reduced Bearing Single Storey Calculator: Worked ExampleA step-by-step worked example of the Raft Slab Reduced Bearing Single Storey calculator, with a screen-recorded video - a raft slab for a single-storey house on 200 kPa ground, from Project Settings to the accepted calculation and its documents.Read Worked exampleHow to Use the Square Pad Foundation Calculator: Worked ExampleA step-by-step worked example of the Square Pad Foundation calculator, with a screen-recorded video - a concrete pad under a verandah post, from Project Settings to the accepted calculation and its documents.Read How-toProject SettingsEvery field on the Project Settings page - what it means, the accepted options and limits, which calculators use it, and what happens to existing calculations when you change it.Read TroubleshootingProject Settings Missing or Out of RangeFix messages such as "Roof Pitch is missing or out of range…" or "Project Settings … is required before running this calculation" by completing Project Settings.Read How-toCheck and Accept ResultsHow to read a calculator's results, choose a passing member, and press Accept so the calculation moves into Project Outputs.Read How-toPay and Download Your DocumentsPay for accepted calculations on Project Outputs, or send the property owner a payment link, then download the Project Summary, Calculations and Drawings.Read