How-to

Choose the right calculator

How calculators are grouped in the app and on the public site, and a quick table to pick the right one from what the member or wall supports.

On this page

ArchiSuite has a calculator for each common member or wall. Pick the one that matches exactly what the member supports. Each calculator only covers the loads it has inputs for.

Where calculators are listed#

In the app#

Click All Calculators in the sidebar. The Engineering Tools page has tabs: All, Foundations, Retaining Walls, Lintels, Floor Beams, Roof Beams, Bracing Portals and Wind Beams.

  • Only calculators that are switched on are shown, so a tab can be empty.

  • Click a card to open that calculator's list of calculations. Then start a new calculation.

  • If you see "The calculator list could not be loaded.", refresh the page. ArchiSuite shows no calculators until it can confirm which ones are available.

All Calculators in the dashboard

On the public site#

The Calculators page groups calculators into families: Beams and Lintels, Masonry Retaining Walls, Foundations, Foundation Walls, Timber Retaining Walls and Bracing Portal Frames.

  • Click See Calculators on a family to open its page.

  • Each calculator there has Use it when, What it gives you and Limits, and an Open the calculator button.

  • All calculators available now lists every calculator with a link to its section.

Public calculator families

Some names differ slightly between the two. For example, the public Timber Pole Retaining Wall is the Timber Retaining Wall card in the app.

Pick by what the member supports#

The Use it when wording below is from each calculator's public page. Open the linked guide for the full detail.

Lintels and beams#

Use it whenCalculator in the appTab
Only trusses or rafters bear on the lintel, with no wall or floor above it. The roof load is spread evenly, with no girder truss or post landing on itLintel Supporting RoofLintels
A wall and floor joists sit on the lintel as well as the roof, and all loads are spread along it, not concentrated at pointsLintel Supporting Roof, Wall & Floor JoistsLintels
Floor joists are the only thing bearing on the beam, and the beam is inside the building and stays dryFloor Beam Supporting FloorFloor Beams
A roof beam carries roof framing (rafters or trusses) only. The form has no point load, wall or floor inputsRoof Beam Supporting Roof Framing/TrussesRoof Beams

Foundations#

Use it whenCalculator in the app
A single-storey house on a pod-and-rib slab, on TC1 land or ground your designer or geotechnical engineer has confirmed is good ground. Posts, girder trusses or beams bearing on the slab can have pads (up to 5)TC1 Single Storey Foundation
A two-storey house with one lightweight suspended upper floor on a pod-and-rib slab, on TC1 land or confirmed good groundTC1 Multi Storey Foundation
A single-storey house on land assessed as TC2, where a stiffened pod-and-rib slab has been confirmed as suitable. Point loads are designed separatelyTC2 Single Storey Foundation
A two-storey house with one lightweight suspended upper floor on land assessed as TC2, with a stiffened pod-and-rib slab confirmed as suitableTC2 Multi Storey Foundation
A single-storey house where the geotechnical report gives an ultimate bearing capacity below 300 kPa but not below 150 kPa, and a pod-and-rib slab with wider footings has been confirmed as suitableRaft Slab Reduced Bearing Single Storey
As above, for a two-storey house with one lightweight suspended upper floorRaft Slab Reduced Bearing Double Storey
You need standalone pads under posts, columns or beam supports, and you have the reactions from the member aboveSquare Pad Foundation

All of these are under the Foundations tab. Read TC1, TC2 and Good ground if you're not sure which applies. The calculators don't work out the technical category, good ground or bearing capacity for you.

Retaining walls#

Use it whenCalculator in the app
A timber pole wall retains no more than 3.0 m at each part, ground behind rises no more than 20 degrees, and any permanent spread load behind is 12 kPa or less. Up to five heights can be designed togetherTimber Pole Retaining Wall
A concrete block wall holds back up to 3,000 mm of soil on its own strip footing, and is not part of a building (wall cases 3 to 6)Cantilever Masonry Retaining Wall
A block basement or lower-level wall is held at its top by a concrete floor slab, retains 2500 mm or less, with level ground behindMasonry Foundation Wall

All three are under the Retaining Walls tab. They need the geotechnical report details and soil properties in Project Settings.

Bracing portals#

Use it whenCalculator in the app
Only roof bears on the portal beam, with no wall or floor above it. You already know the wind and earthquake BUs the portal must provide, and a steel portal suits the openingBracing Portal Supporting Roof Only
The portal sits under an upper-storey wall and floor, and one or more floor beams bear on the portal beam. You know the wind and earthquake BUs neededBracing Portal Supporting Roof, Wall, Floor & Beams
The portal sits under an upper-storey wall and floor, and no floor beams bear on the portal beam. You know the wind and earthquake BUs neededBracing Portal Supporting Roof, Wall, and Floor

Both are under the Bracing Portals tab. See Bracing unit.

Check what isn't covered#

Before you start, check the calculator's Limits on its public page or guide. Things the public pages list as not covered include:

  • Lintels and beams: point loads such as a girder truss, post or other beam landing on the member; cantilevered or multi-span (continuous) members; supports on timber piles or any foundation other than a concrete slab edge; site-specific wind design, sites above 800 m, or roof pitches over 45 degrees.

  • Foundations: TC3 land; ground below 150 kPa, or soft, expansive or settlement-prone ground; proprietary raft or pod slab systems; houses of more than two storeys; point loads on TC2 slabs.

  • Retaining walls: walls that form part of a building or directly support one (except the propped wall); retained heights over the limits above; water pressure behind the wall; overall slope stability.

  • Bracing portals: working out how many BUs a wall line needs; timber or hollow-section portals; multi-bay frames; roof point loads on the portal beam, such as from girder trusses or ridge beams.

If your design falls outside these, see When no calculator fits.

Tips#

  • Choose by what is actually bearing on the member, not by what the opening is called.

  • Set up Project Settings first. Tick the matching What are you designing? categories so only the site settings you need are shown.

  • If a member doesn't pass, see No member passes before switching calculators.

Was this helpful?